SET (Setting) Mode
Section 6-1
4.
Set the timeout time for decode processing of a single image
read. (Setting range: 200 to 2,000 ms; default setting: 500 ms.)
5.
Select the number of times reading is repeated in the event of in-
correct reading. A fresh image will be obtained and reading per-
formed for the number of times specified. (Setting range: 0 to 9;
default setting: 0.)
Normal Procedure
1,2,3...
1.
Select Read QR (Normal).
2.
Select Reading Settings (Manual).
The parameters will be displayed.
3.
Edit the parameters as required.
4.
Select Register.