92
Connection Examples
Section 4-5
Communication Settings
• V530-R150 Settings
page 194 and page 196
• Programmable Controller Settings
Program Examples
This program inputs a One Shot Reading Command to the Program-
mable Controller’s DM. The V530-R150 references this command
and reads the data. The reading data is written to the specified words
in the Programmable Controller.
1,2,3...
1.
Set the reading conditions of the V530-R150 and set the reading
mode to RUN mode.
2.
Set the Start Reading Command in DM0100 of the Programma-
ble Controller.
The V530-R150 reads codes, sets the Write Flags in DM0110,
and writes the reading data to DM words beginning with DM0111.
Item
Setting
Communication setting
Baud rate
The same settings as
those of the Program-
mable Controller.
Data length
Parity bits
Stop bits
Mode
Host link
Host Link setting
Read area
DM
Begin read word
0100
Write area
DM
Begin write word
0110
Item
Setting
Communications mode
SYSWAY (Host Link)
1 : 1 / 1: N
1 : N
Unit No.
00
Baud rate
Match the settings with a V530-R150
Data length
Parity bits
Stop bits
Summary of Contents for V530-R150E-3 -