1,2,3...
1.
Select a trigger mode for TRIG B.
2.
Select whether the OK/NG terminal is turned ON for an OK read-
ing or an NG reading.
3.
Set the output period for reading judgment. Set a value between
2.0 and 10000.0 ms that is greater than the rising time + output
time, and less than the reading interval. If the cycle is longer than
the reading interval, the output timing will fall behind as the read-
ings are repeated.
(The default setting is 10.0 ms.)
4.
Set the time from when the result is output to the terminal block
to when the GATE signal is turned ON. This time is used to wait
until the data output becomes stable. Set a time between 1.0 and
1000.0 ms that is longer than the delay time for the external de-
vice.
(The default setting is 1.0 ms.)
5.
Set the time during which the GATE signal is ON. Set a value be-
tween 1.0 and 1000.0 ms so that the external device can read the
reading judgment. (The default setting is 5.0 ms.)
Output Settings
Continuous
(Default)
Performs continuous reading while the TRIG B termi-
nal is turned ON. In this mode, the settings for reading
accuracy and the number of retries are invalid with
TRIG B input.
Level trig (trig-
ger)
Repeats reading until an OK (readable) reading judg-
ment is output while the TRIG B terminal is ON. In the
case of an NG (not readable) reading, the NG signal is
output when the TRIG B is turned OFF.
NG: ON
(Default)
The OK/NG terminal is turned ON for an NG reading.
OK: ON
The OK/NG terminal is turned ON for an OK reading.
Output Settings
Summary of Contents for V530-R150E-3 -
Page 7: ......
Page 9: ......
Page 17: ......
Page 27: ......
Page 47: ......
Page 63: ......
Page 224: ...207 System Section 6 4 2 Set each item 3 Select End before leaving this screen...
Page 226: ...209 System Section 6 4 2 Select the error method 3 Select End to leave this screen...
Page 263: ......
Page 279: ......
Page 281: ......
Page 283: ......
Page 289: ......