85
Trigger Inputs and Output Format
Section 4-3
One Shot Reading (10) 1:1 Connection
Reading ends and the judgments are output when the reading is cor-
rectly performed. When the reading is not correctly performed, read-
ing continues to be performed for the number of retries specified in
the setting conditions. The reading judgments are output to a write
word.
Read
Continuous Reading (11, 12) 1:1 Connection
Starts continuous reading
Continuous reading is performed.
The reading judgment is output to a write word.
Read
Stops continuous reading.
Read
Reading Judgment
Write
• Reading data is stored with ASCII codes.
• Write flag switches between [0 0 0 0]
[1 1 1 1] each time
data is output. Monitor the flag to see whether reading judgment
has been written.
Begin read
word
Bit
Setting
15 to 12
11 to 8
7 to 4
3 to 0
+0
0 0 0 0
0 0 0 0
0 0 0 1
0 0 0 0
Command code
Begin read
word
Bit
Setting
15 to 12
11 to 8
7 to 4
3 to 0
+0
0 0 0 0
0 0 0 0
0 0 0 1
0 0 0 1
Command code
Begin read
word
Bit
Setting
15 to 12
11 to 8
7 to 4
3 to 0
+0
0 0 0 0
0 0 0 0
0 0 0 1
0 0 1 0
Command code
Begin write word
Bit
15 to 12
11 to 8
7 to 4
3 to 0
+0
Write flag
0 0 0 0
0 0 0 0
0 0 0 0
+1
Reading data 1st byte
Reading data 2nd byte
+2
Reading data 3rd byte
Reading data 4th byte
to
to
to
+27
Reading data 53th byte
Reading data 54th byte
+28
Reading data 55th byte
Reading data 56th byte
Summary of Contents for V530-R150E-3 -
Page 7: ......
Page 9: ......
Page 17: ......
Page 27: ......
Page 47: ......
Page 63: ......
Page 224: ...207 System Section 6 4 2 Set each item 3 Select End before leaving this screen...
Page 226: ...209 System Section 6 4 2 Select the error method 3 Select End to leave this screen...
Page 263: ......
Page 279: ......
Page 281: ......
Page 283: ......
Page 289: ......