146
SET (Setting) Mode
Section 6-1
Data 0 to 3: The data read in the next trigger is registered as the
number of standard data.
Verify:
Every time reading is performed, the registered
standard data and reading data are verified.
The judgment result is output to the terminal block
(DO0 to DO3) and RS-232C (Normal).
When outputting to the terminal block, data 0 to 3 are
output to DO0 to DO3.
When outputting to the RS-232C interface, the data
numbers are attached to the output format.
OFF:
No judgement is performed. (Default setting)
Clr Data:
The registered data is cleared.
3.
This function displays the data from the start of reading to the
end.
ON:
The following 4 items are counted and displayed. If
the data is saved to flash memory, the count PVs will
be retained even if the power is turned OFF.
*Total number of reads
*Read Accuracy (OK reads
Total reads)
*Number of OK reads
*Error code
OFF:
The data history is not displayed. Select OFF to re-
set the data history. (Default setting)
4.
This function displays the Reading Data and the Read Accuracy.
ON:
Ten reads are performed for a single trigger input.
The Read Accuracy and the Reading Data for the
tenth read are displayed on the screen and output
through RS-232C with normal (no protocol) commu-
nications.
OFF:
The Read Accuracy is not displayed. (Default set-
ting)
Summary of Contents for V530-R150E-3 -
Page 7: ......
Page 9: ......
Page 17: ......
Page 27: ......
Page 47: ......
Page 63: ......
Page 224: ...207 System Section 6 4 2 Set each item 3 Select End before leaving this screen...
Page 226: ...209 System Section 6 4 2 Select the error method 3 Select End to leave this screen...
Page 263: ......
Page 279: ......
Page 281: ......
Page 283: ......
Page 289: ......