background image

 

TaoTronics TT-BS007 

Wireless Laser Barcode Scanner 

User

s Manual 

 

 
 
 
 
 
 
 

 
 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 
 
 
 

Summary of Contents for TT-BS007

Page 1: ...TaoTronics TT BS007 Wireless Laser Barcode Scanner User s Manual ...

Page 2: ...all one dimensional bar codes It can be used in supermarkets warehouse logistics books banking transportation postal and industrial manufacturing factory production process management and other fields Its main features are Ø Excellent scanning performance Ø Fashionable design lightweight and flexible convenient and quick Ø Completely independent intellectual property rights Ø Unique communication ...

Page 3: ...3 Connect external antenna base Receiver Indicator Connect USB Interface Charge bottom Circular charger Bottom view of the scanner Front view of Receiver Bottom view of Receiver Top view of Receiver ...

Page 4: ...or restore factory settings in common functions of bar code setting to clear stored bar codes that is scanning resumed only when the storage space is non full 4 Low power consumption If the scanning system doesn t scan bar codes within the set time scanning guns will automatically enter the shutdown state Users can set off time according to their own needs the scanner won t shut down when there ar...

Page 5: ...Initial installation follow these steps 1 Connect the receiver to an external antenna tighten the screws 2 Connect one end of the USB cable to the receiver s USB port and then the other end connected to the computer s USB cable port the indicator light at the receiving end is blinking after the success of connection 3 Create a new text input box on the computer the cursor at the open text entry bo...

Page 6: ...n and the receiver is too far or environmental interference the transmission will fail then wireless scanner automatically stores scanned bar codes After communication restored according to the FIFO principle the gun automatically send stored barcodes When the bar code sending fails for storage the buzzer sounded Didi twice to prompt There are two reasons for the failure of bar code sending one is...

Page 7: ... and a half hours the power indicator light flashes charging power indicator lights long 9 Matching Network When leaving factory scanner and receiver have been paired under normal circumstances users no longer need to match If users need to re pair follow these steps 1 Switch on the scanner 2 Pull out the receiver s USB cable from the computer and make sure that USB cable and the receiver is conne...

Page 8: ...follows these steps 1 Switch on the first scanner 2 implementation of the above 1 on 1 match process 3 pairing is successful said the first scanner is in network called as 1 on 1 mode 4 Switch on the second scanner the same execution of 1 to 1 match process successful matching shows that the second scanner has access to network called as 2 to 1 mode 5 Switch on the third scanner the same execution...

Page 9: ... the receiver s USB cable to the computer within 5 seconds d If the scanner buzzer Didi tick three times said the pairing is successful if given a dee dee dee dee dee dee said pairing failed e If the pairing fails repeat steps a b c 5 If the pairing is successful it shows that the matching of 1 on 2 network is successful and can be used 10 Common features of bar code setting 1 on 1 match Scanned t...

Page 10: ...on t shut down automatically when no operation is done H Y C O C M D S D Keyboard mode output of the receiver Finished this scanning command the receiver will switch to keyboard mode output H Y C O C M D K B Restore factory setting Scanned this bar code the wireless scaner will restore factory setting H Y C O C M D D E F A U L T Open the storage function Set that when scan normally the data will b...

Page 11: ...switch on H Y C O C M D T X Close wireless transmission Scanned this barcode close wireless transmitted barcodes whatever the internet condition is H Y C O C M D D I S T X Factory setting 20 seconds sleep time open storage clear the pairing information After scanning the bar code to restore factory settings above the type and parameters of open the bar code identifying remain unchanged In addition...

Page 12: ...On Output of leadcode On CODE128 Decode On Identify mini length 4 Identify max length 50 CODE39 Decode On Identify mini length 5 Identify max length 50 Error check Off Output of check code On FULLASCII On CODE93 Decode Off Identify mini length 8 Identify max length 50 CODE11 Decode Off Identify mini length 8 Identify max length 50 Error check Off Output of check code On GS1 Decode Off ...

Page 13: ...A25 Decode Off Identify mini length 8 Identify max length 50 Error check Off Output of check code On MATRIX25 Decode Off Identify mini length 8 Identify max length 50 Error check Off Output of check code On CHINESE25 Decode Off Identify mini length 8 Identify max length 50 CODABAR Decode On Identify mini length 8 Identify max length 50 MSI Decode Off Identify mini length 8 ...

Page 14: ... Laser Safety Standard Level 2 Dimensions of Scanner L W H 164mm 67mm 95mm Dimension of Receiver L W H 18 5mm 45mm 70mm Case materials ABS TPU aluminium alloy Weight of Scanner 180g including battery Weight of Receiver 60g Using method Handheld Scanning method Manual Continuous automatic Indicator Two color LED blue red Buzzer Programmable tone and volume ...

Page 15: ...d Resolution 0 10 0 825mm BER 1 8 000 000 Decode Capability EAN8 EAN13 UPC_A UPC_E CODE128 CODE39 CODE93 CODE11 GS1_DATABAR ITF25 INDUS25 IATA25 MATRIX25 CHINESE25 CODABAR MSI and other 1D barcodes Battery 3 7V 1000mAh Charging time 2 5h Theoretical Service time 30h Operating Current 85mA Quiescent Current 30mA Elevation angle 60 Inclination angle 45 Radio Frequency 433MHz ...

Page 16: ... 15kVDC air discharge 8kVDCdirect indirect discharge Anti drop capability 1 5m Light intensity 4 000luX max daylight Electromagnetic interference Conforms to en50081 par1 specification External electromagnetic interference Conforms to en50082 par1 specification Dust andwaterproof Conforms to iec529 ip42 specification 13 Troublesolving Problems Possible reasons Possible solutions Follow the The sca...

Page 17: ...his bar code type hasn t been switched on Make sure that the identification option of the barcode has been switched on then try to scan bar codes of the same type The barcode is longer than corresponding maximum and minimum length limit Make sure the barcode s length is in the range of max and mini length Bar code symbol unreadable Check the symbols to make sure that they re unharmed and try to sc...

Page 18: ...ng because of the stored data Empity the stored data Open the receiver receives bar code Or scan close storage function in common fuctional setting of barcode which will empity all the stored barcodes then the warning alarm will stop If you need storage please re scan open storage After successful scanning thedata doesn t appear on PC Output mode is not correct See to switch to serial mode output ...

Page 19: ...sories date batch number as an evidence of in and out of the warranty period equipment without notice or any warranty certificate will be treated as a case out of the warranty period do not erase all the numbers on the device or the company has the right to refuse to give warranty 5 When equipment needs repair send back the whole machine and parts used for test if the customer disassembles the mac...

Page 20: ...N C 3 0 1 0 3 0 1 F N C 3 0 1 0 3 0 0 F N C 3 0 1 0 4 0 1 F N C 3 0 1 0 4 0 0 F N C 3 0 1 0 4 0 3 F N C 3 0 1 0 4 0 2 F N C 3 0 1 0 5 0 1 F N C 3 0 1 0 5 0 0 2 Switching of identifying types Users can manually switch on or off a bar code identification Switching on is to set bar codes by scanning the open identity of corresponding bar code types switching off is to set bar codes by scanning the cl...

Page 21: ...ion CODE39 Open Identification CODE93 Close Identification CODE93 Open Identification CODE11 Close Identification CODE11 code types The bar code is setted as CODE128 so all CODE128 types can not be closed F N C 3 0 2 0 1 0 1 F N C 3 0 2 0 1 0 0 F N C 3 0 2 0 2 0 1 F N C 3 0 2 0 2 0 0 F N C 3 0 2 0 3 0 1 F N C 3 0 2 0 3 0 0 F N C 3 0 2 0 4 0 1 F N C 3 0 2 0 4 0 0 F N C 3 0 2 0 5 0 1 F N C 3 0 2 0 5...

Page 22: ...5 Close Identification IATA25 Open Identification MATRIX25 Close Identification MATRIX25 Open Identification CHINESE25 Close Identification CHINESE25 F N C 3 0 2 0 6 0 1 F N C 3 0 2 0 6 0 0 F N C 3 0 2 0 7 0 1 F N C 3 0 2 0 7 0 0 F N C 3 0 2 0 8 0 1 F N C 3 0 2 0 8 0 0 F N C 3 0 2 0 9 0 1 F N C 3 0 2 0 9 0 0 F N C 3 0 2 1 0 0 1 F N C 3 0 2 1 0 0 0 F N C 3 0 2 1 1 0 1 F N C 3 0 2 1 1 0 0 ...

Page 23: ...te bar code types if the maximum and minimum length limit is set to 0 that is to set to identify any length Setting steps 1 Scanning the maximum length bar code of corresponding barcode type 2 Digital bar codes scanning see page 29 For example if the user needs to enter 15 scanning the bar code number 1 and then scanning bar code 5 3 Scan the confirmation to set bar codes see page 30 if this step ...

Page 24: ... ITF25 Max length limit ITF25 Mini length limit INDUS25 Max length limit INDUS25 Mini length limit IATA25 Max length limit IATA25 F N C 3 0 3 0 3 0 0 F N C 3 0 3 0 3 0 1 F N C 3 0 3 0 4 0 0 F N C 3 0 3 0 4 0 1 F N C 3 0 3 0 5 0 0 F N C 3 0 3 0 5 0 1 F N C 3 0 3 0 6 0 0 F N C 3 0 3 0 6 0 1 F N C 3 0 3 0 8 0 0 F N C 3 0 3 0 8 0 1 F N C 3 0 3 0 9 0 0 F N C 3 0 3 0 9 0 1 ...

Page 25: ... 3 1 3 0 0 F N C 3 0 3 1 3 0 1 F N C 3 0 3 1 4 0 0 F N C 3 0 3 1 4 0 1 4 Output switch setting of check codes This group of settings is used to set whether send out check codes of corresponding bar code types or not Users can manually open or close the check codes output of specified bar code types according to their own needs Switching on is to set bar codes by scanning open check codes output of...

Page 26: ...k code EAN8 Close check code EAN8 Open check code UPCA Close check code UPCA Open check code UPCE Close check code UPCE F N C 3 0 4 0 1 0 1 F N C 3 0 4 0 1 0 0 F N C 3 0 4 0 1 1 1 F N C 3 0 4 0 1 1 0 F N C 3 0 4 0 2 0 1 F N C 3 0 4 0 2 0 0 F N C 3 0 4 0 2 1 1 ...

Page 27: ...de CODE39 Open check code CODE11 Close check code CODE11 Open check code ITF25 Close check code ITF25 F N C 3 0 4 0 2 1 0 F N C 3 0 4 0 4 0 1 F N C 3 0 4 0 4 0 0 F N C 3 0 4 0 6 0 1 F N C 3 0 4 0 6 0 0 F N C 3 0 4 0 8 0 1 F N C 3 0 4 0 8 0 0 ...

Page 28: ... 0 5 Switch setting of error checking Some bar code types have error checking code the code value can be used to check the bar code is correctly identified or not If switching on error checking then use the check code and bar code characters to verify the check is error then recognition errors no output of bar code Users can manually open or close the error checking of specified bar code types acc...

Page 29: ...ing bar code types switching off is to set bar codes by scanning the close error checking of corresponding bar code types Warning Because the check code of bar code may be used for verification and bar code character so used in front of bar codes whose specific properties haven t been identified please use this feature with caution F N C 3 0 5 0 4 0 1 F N C 3 0 5 0 4 0 0 F N C 3 0 5 0 6 0 1 F N C ...

Page 30: ...tput settings This group of setting is to set whether send out the leadcode of corresponding bar codes or not users can manually open or close the leadcode output of a particular bar code Switching on is to set bar codes by scanning open leadcode of corresponding bar code types switching off is to set bar codes by scanning the close leadcode of corresponding bar code types F N C 3 0 6 0 1 0 1 F N ...

Page 31: ...put of a particular bar code Switching on is to set bar codes by scanning open complement output of corresponding bar code types switching off is to set bar codes by scanning the close complement output of corresponding bar code types On When there is no identification to complement that it is wrong identification not output of bar code correct identification to the complement output of bar code c...

Page 32: ...end out bar code characters plus complement characters when identified no complement only send out bar code characters F N C 3 0 7 0 1 0 1 F N C 3 0 7 0 1 0 0 F N C 3 0 7 0 1 0 2 8 FULL ASCII switch setting Because only CODE39 has FULL ASCII conversion therefore such setting is only effective to CODE39 bar codes Users can manually switch on or off FULL ASCII set On Identify CODE39 bar codes used F...

Page 33: ...umber is up to 500 more than 15 and less than or equal to 30 characters including RET orTAB the maximum storage number is 256 close the scanning head if the storage number is up to 250 more than 30 and less than or equal to 45 characters including RET orTAB the maximum storage number is170 close the scanning head when the storage number is up to166 When scans HYCOCMD NUMBAR identifys only numbers ...

Page 34: ... all of the characters and numbers in the identified bar code namely switch on HYCOCMD ALLBAR 10 Numeric codes Bar codes from number 0 to 9 are auxiliary bar codes of bar code setting F N C 3 1 1 0 1 0 0 F N C 3 1 1 0 1 0 1 F N C 3 1 1 0 1 0 2 F N C 3 1 1 0 1 0 3 F N C 3 1 1 0 1 0 4 F N C 3 1 1 0 1 0 5 ...

Page 35: ... of configuration The bar codes cancel and confirmation are auxiliary bar codes bar code setting F N C 3 1 2 0 1 0 1 F N C 3 1 2 0 1 0 0 12 Power setting This setting is advanced setting users can set appropriate power of the scanner according to the network needs in actual applications Users should use this setting with caution after consulting the dealer or factory ...

Page 36: ...M D P W R 2 0 200m Level7 H Y C O C M D P W R 1 7 160 m Level6 H Y C O C M D P W R 1 4 120 m Level 5 H Y C O C M D P W R 1 1 100 m Level 4 H Y C O C M D P W R 0 8 80m Level 3 H Y C O C M D P W R 0 5 60m Level 2 H Y C O C M D P W R 0 2 40m Level 1 H Y C O C M D P W R 0 1 20m ...

Page 37: ... should be installed when switch to serial mode If not installed every time when connect USB to PC Installation Instruction pops up the PC will not able to switch back to keyboard mode in the case of not installing the driver and scanned data can not be transferred ...

Reviews: