40
Timing Chart
Section 3-3
Output Terminals
Input Terminals
Terminal
Function
RUN
Turns ON during RUN mode.
BUSY
Shows that the V530-R150 is reading an image, changing settings, etc.
Do not input the next command while the BUSY signal is ON.
Otherwise, the commands input during command execution or processing may
not be properly executed.
OK/NG
Outputs the judgment under the set reading conditions.
(Can be set to turn ON for either OK or NG judgment.)
GATE
Used to control the timing with which the reading judgment is read at the external
device.
The duration for which the GATE terminal is turned ON can be set as required for
the external device to correctly read the reading judgment.
Make the output cycle longer than the gate ON delay plus the gate ON time, but
shorter than the duration of the reading.
If the cycle is longer than the duration of the reading, the output timing falls
behind as readings are repeated.
Gate ON delay, Gate ON time and Output period are set under the set communi-
cations conditions.
page 199
Terminal
Function
TRIG B
Continuous reading is performed when TRIG B signal is turned ON.