background image

H

eavy Duty Reader

ELECTRONIC SUPPORT SERVICE
iseozero1

.com

®

i s e o

. c o m

Iseo Serrature s.p.a 
Via San Girolamo 13 
25055 Pisogne (BS) 
ITALY
Tel. +39 0364 8821 
[email protected]

Non contractual document. Subject to change. Cod. 600000E03201 - 10/09/2018

Heavy Duty Reader (EN) - © 2018  Iseo Serrature S.p.a. - www.iseo.com

INSTALLATION GUIDE

1. TECHNICAL SPECIFICATIONS

Wall mounting antivandal heavy duty reader/writer for F9000 keys.

PRODUCT:

- Solid metal antivandal housing: impact protection grade IK10.
- All weather outdoor usage: IP66, IP67 and IP69 protection grade.
- High corrosion resistance: tested for 480 hours in NSS (Neutral Salt Spray chamber).
- Security fixing screws.
- Ability to replace the mechatronic cylinder core.
- No sharp edges (all rounded edges).
- RS485 interface.
- Power supply: by Atlas
- Power consumption: 2W
- Multicolor signaling LEDs (green, blue, red).
- LxDxH = 150 x 90 x 53 mm

FEATURES:

EN60068-2-1, EN60068-2-2, EN60068-2-3, IEC 60529, IEC 62262.

CERTIFICATIONS:

- Operating temperature: -40°C ÷ +80°C
- Storage temperature: -40°C ÷ +80°C
- Humidity: max 93% without condensation 

ENVINRONMENTAL CHARACTERISTICS:

2. PACKAGE CONTENTS

Back cover 

fixing plate

1x

1x

Adhesive 

gasket

Security fixing 

screws

4x

Torx TR20 x 100

(M4 x 8)

Cable

gasket

1x

Front cover with 

Electronic board

1x

90

150

53

UM = mm

 4. DIMENSIONS

40

120

ø

6

26

7

5. ELECTRICAL CONNECTIONS

TX/RX 485 (A)
TX/RX 485 (B)

(10 

÷

 24 Vdc)

(GND)

Heavy Duty Reader

connector (RS485)

- Wiring cable not included in the kit.
- Recommended cable: Ethernet 
  cable FTP AWG24 CAT5E (and above 
  or equivalent data cable).
- Min/max cross-section of the wires: 
  0.20÷1.5mm

2

 (24÷15AWG).

- Min/max cable diameter: 3÷7mm
- Max length: up to 500mt

R

6. ELECTRICAL CONNECTIONS: ATLAS TYPE AND CONNECTORS

Wall fixings not provided in the kit. The installator must choose the most suitable fixings according to the 
wall type and material. ISEO recommends to install the Heavy Duty Reader in a concerete wall by M10 steel 
anchors with M6 bolts. 

Minimum recommended traction load for anchors: 150Kg.
Maximum bolts diameters 6mm.
Maximum bolts head dimension:    14mm diameter x 6mm thickness.

1

2

R = 120 ohm - 1/4 W

(Supplied with the reader)

3.1 WARNINGS

Read this manual prior to use the device in order to ensure a safe and proper use.
Preserve this manual as future reference.

The installation of the device requires the intervention of qualified staff, adequately trained by ISEO.

The instructions should be carefully followed during the use of the product. These instructions should be 
passed on by the installer to the user.

No modifications of any kind are permitted, except for those described in these instructions.

The product must be destined only for the use for which it is expressly designed and therefore as an heavy duty 
reader and writer unit for civil and industrial locations. Any other use is considered improper and dangerous.

Keep the 

Front cover 

inside its box during the installation of the 

Back cover fixing plate

, to prevent 

drilling residues from entering inside the 

Electronic board

.

Use the 

Adhesive gasket

 only in case of not-straight or no flat wall. If the 

Adhesive gasket

 is required, 

take care to uniformly apply it to seal the reader to the wall, in order to avoid any water penetration. 

Check if the 

Back cover gasket

 is correctly fitted in the slot. If not re-position it correctly in order to avoid 

any water penetration. 

Do not enlarge, damage or modify the 

Cable gasket

, failure to do that it could compromise the water 

sealing. Use a max cable diameter of 7mm to ensure the cable passage through the cable gasket hole.

Check the 

Wiring cable 

perfectly fits inside the 

Cable gasket 

hole without leaving any space that could 

allow water penetration. Use a min cable diameter of 3mm to ensure the cable gasket impermeability.

  3. WARNINGS

Back cover

gasket

ATLAS DIN 

ATLAS STANDARD (STD)
ATLAS PLUS 

CH1 

4

3

2

1

(GND)

CH2 

4

3

2

1

5
6

CH2 

4

3

2

1

(GND)

CH1 

4

3

2

1

(GND)

ø

min.3mm

max.7mm

ø

1x

R = 120 ohm - 1/4 W

(Connect to ATLAS)

Reviews: