Trigger Inputs and Output Format
Section 4-3
Read Measurement Time (@MT) 1:1 Connection
Reads the most recent read-processing time.
Send
Receive
The 5-digit processing time (00000 to 99999 ms) is returned if the
command was executed correctly.
A value of 99999 will be returned if the actual processing time
exceeds 99,999 ms. A value of 00000 will be returned if the process-
ing time could not be read.
Example: A value of 00230 will be returned when the most recent
processing time was 230 ms.
Change Display (@DC) 1:1 Connection
Changes the image display status.
Send
Set the display code to 0 to specify Through display or 1 to specify
Freeze display.
Through display: 0
Freeze display:
1
Receive
“OK” indicates that the command was executed correctly:
“ER” indicates that the command was not executed correctly:
@ M T <Footer>
<Processing time>
<Footer>
<Header>
@ D
<Footer>
C
<Display code>
O K <Footer>
<Header>
E R <Footer>
<Header>