111
STEP 2 Setting Reading Conditions
Section 5-3
10. Press the ESC Key once to go back to the window shown in step
7.
11. Press the ESC Key once more to return to MON (monitor) mode.
12. Press the TRIG Key on the Console to perform one reading.
Parameters are set based on the data obtained with this reading.
Note
If reading is performed successfully, the teaching function will
automatically turn OFF. To repeat the teaching operation, go back
to SET mode and repeat the procedure from step 7.
These parameters can be displayed and changed if necessary
from Reading Settings (Manual).
page 161
If reading is not performed correctly, the teaching function will stay
ON. To turn the teaching function OFF, select Reading Settings
The parameters obtained are displayed.
These parameters are used as settings.
In RUN mode, only the read data (ABCDE12345
in this example) is output to RS-232C.