background image

                                     

 

 

 

                           

 

                                                       

 

 

 

 

 

 

 

ValueScan II

TM

 

Barcode Scanner 

 

User‟s Manual 

 

 

 

 

 

 

80104502-001 rev.A 

Summary of Contents for ValueScan II

Page 1: ...ValueScan IITM Barcode Scanner User s Manual 80104502 001 rev A ...

Page 2: ...g conditions this device may not cause harmful interference and this device must accept any interference received including interference that may cause undesired operation CANADIAN DOC STATEMENT This digital apparatus does not exceed the Class B limits for radio noise for digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le présent apparei...

Page 3: ... item of equipment whether that defect is warranted against or not Purchaser s sole and exclusive remedy for defective equipment which does not conform to the requirements of sales is to have such equipment replaced or repaired by ID TECH For limited warranty service during the warranty period please contact ID TECH to obtain a Return Material Authorization RMA number instructions for returning th...

Page 4: ... information contained herein is provided to the user as a convenience While every effort has been made to ensure accuracy ID TECH is not responsible for damages that might occur because of errors or omissions including any loss of profit or other commercial damage The specifications described herein were current at the time of publication but are subject to change at any time without prior notice...

Page 5: ...upply DC adapter to the interface cable of the scanner 3 Plug the serial connector into the serial port on the back of your computer terminal Tighten the two screws to secure the connector to the port 4 Plug the power pack into a power source 5 Once the scanner has been fully connected turn the terminal computer power back on USB Simulates keyboard wedge 1 Connect the USB cable to the terminal com...

Page 6: ...um Transmission Enable Code ID UPC A V V V A UPC E V V V E EAN 13 V V V F EAN 8 V V V FF Code 39 V Interleaved 2 of 5 V I Industrial 2 of 5 I IATA I Matrix 2 of 5 B Codabar Code 128 V V Code 93 V two digits Code 11 V one digit O MSI Plessey V UK Plessey V Telepen S Standard 2 of 5 I GS1 DataBar Omnidirectional R4 GS1 DataBar Limited RL GS1 DataBar Expanded RX China Post t Italian Pharmacode p ...

Page 7: ... CODE 39 500Lux PCS 90 20mils Scanning Width 50 mm wide 10mm Scan Speed 100 scans sec Resolution 0 1mm 4mils Code39 PCS 90 Print Contrast 45 or more Scanning Angle Pitch 60 Yaw 70 Decode Capability Auto discriminates all standard one dimension barcodes Beeper Operation 7 tones or no beep Indicator Green led and beep sound Mechanical Length 176 mm Width handle 40 mm Width head 67 mm Depth handle 30...

Page 8: ...ing Max 150 mA 5 VDC Current Standby 30 mA 5 VDC DC Transformers Class 2 5VDC 450 mA Agency listing FCC Class A CE Environmental Operating Temperature 0 to 45 32 to 113 Storage 20 to 60 4 to 140 Humidity 10 to 90 relative humidity non condensing Light Level Up to 20000 Lux Shock 1 5m drop onto concrete Contaminants Sealed to resist airborne particulate contaminants Ventilation None required ...

Page 9: ...election check digit selection Decoding option Transmitted character delay Header selection trailer selection message suffix good read beep tone and volume scanner trigger selection Keyboard emulation type intermessage delay keyboard type and keyboard language Serial interface type ACK NAK Xon Xoff RTS CTS good read LED control start stop bits ...

Page 10: ...option you must 1 Scan the Program barcode on the parameter setting part 2 Enter the option mode by scanning the Option Bar Code also on the Parameter setting part 3 To the right of the option barcode the necessary alphanumeric inputs are listed Scan these alphanumeric entries from the back fold out page To confirm above steps you must scan the Finish barcode on the back fold out page 4 Once you h...

Page 11: ... Code Option Alphanumeric Entry Scanning mode Good read off Momentary Alternate Timeout off Continue Test only 00 01 02 03 04 05 Program Exit Program Barcode Option Barcode Exit Barcode Back Fold Out Finish barcode ...

Page 12: ...ill need to select an appropriate model for a specific interface Interface selection The factory interface default can not be changed for other type interfaces One specific model only supports the appropriate host interface For the appropriate model numbers of ValueScan II for various PC computer terminal interfaces please consult the ID TECH website www idtechproducts com ...

Page 13: ...he wedge is a fairly simple process without any changes of software or hardware Keyboard Type ValueScan II keyboard wedge model only supports keyboard interface with PS 2 type connector Option Bar Code Option Alphanumeric Entry Keyboard type IBM PS 2 Reserved Reserved Reserved Reserved Reserved Reserved 00 01 02 03 04 05 06 Program ...

Page 14: ...characters of barcode have been lost you may need to set 05 or 06 to match your host keyboard speed Function Key Set Enable scanner can output code as pressing function key in your application program while the barcode data contain an ASCII value between 0116 to 1F16 Refer to the ASCII table Numeric Key The Keypad has to be selected if your application program is only acceptable for keypad numeric...

Page 15: ... France Germany Italian Portuguese Spanish Swedish Switzerland UK Latin American Japanese 00 01 02 03 04 05 06 07 08 09 10 11 12 Function key Disable Enable 00 01 Numeric key Alphabetic key Numeric keypad Num lock state only Alt Keypad 00 01 02 ...

Page 16: ...keyboard timing and passes keyboard present status to the PC during power on Inter character delay This delay is inserted after each data character is transmitted If the transmission speed is too high the system may not be able to receive all characters Adjust it and try out a suitable delay to make the system work properly Block transmission delay It is a delay timer between barcode data output T...

Page 17: ...Bar Code Option Alphanumeric Entry Caps lock Caps lock ON Caps lock OFF 00 01 Power on simulation Disable Enable 00 01 Inter character delay 00 99 msec 00 99 02 Block transmission delay 00 99 10 msec 00 99 10 Program ...

Page 18: ...er will issue a 5 beep warning Xon Xoff When the host computer is unable to accept data it sends an Xoff code to inform the scanner to suspend data transmission and an Xon code to continue ACK NAK When the ACK NAK protocol is used the scanner waits for an ACK acknowledge or not acknowledge from the host computer after data transmission and will resend in response to a NAK Inter character delay It ...

Page 19: ...ode Option Alphanumeric Entry Flow control None RTS CTS Xon Xoff ACK NAK 00 01 02 03 Inter character delay 00 99 msec 00 99 00 Block transmission delay 00 99 10 msec 00 99 00 Response delay 00 99 100 msec 00 99 20 Program ...

Page 20: ...ion Alphanumeric Entry Baud rate 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS 00 01 02 03 04 05 06 07 Parity None Odd Even 00 01 02 Data bits 8 bits 7 bits 00 01 Stop bit One bit Two bits 00 01 Program ...

Page 21: ...6P Female 1 DATA PC CLK KB 2 NC GND 3 GND DATA KB 4 VCC 5V VCC 5V 5 CLK PC NC 6 NC NA RS 232 DB 9F Connector To Host Side Pin Definition 1 NC 2 TXD 3 RXD 4 NC 5 GND 6 NC 7 CTS 8 RTS 9 VCC 5V 4 2 3 1 8 6 9 7 5 3 1 2 4 5 Mini DIN 6P Female Connector 3 4 5 6 2 1 Mini DIN 6P Male Connector 6 ...

Page 22: ...uccessful read the scanner will beep to indicate a good barcode read and its Beep loudness Beep tone freq and Beep tone duration are adjustable Beep loudness Beep tone freq Beep tone duration You can adjust Beep Loudness Beep tone and Beep duration for a good read to your personal preference note In Beep tone frequency setting 00 10 are used to set to Melody 0 10 and not for tone frequency 0 1000 ...

Page 23: ...umeric Entry Power on alert Disable Enable 00 01 LED indication Disable Enable 00 01 Beeper indication Disable Enable 00 01 Beep loudness 00 07 00 07 07 Beep tone freq 00 99 100Hz 00 99 27 Beep tone duration 00 99 10 msec 00 99 10 Program ...

Page 24: ... symbol s data The position default value is 00 to indicate no character insertion Also make sure insertion positions are not greater than the symbol s length otherwise the insertion data is not effective Code ID position To suit your preference the transmitting position of the Code ID can be placed Before Code Data or After Code Data when it is transmitted Option Bar Code Option Alphanumeric Entr...

Page 25: ...sertion 00 63 00 Insert data group 2 position 00 63 00 no insertion 00 63 00 Insert data group 3 position 00 63 00 no insertion 00 63 00 Insert data group 4 position 00 63 00 no insertion 00 63 00 Code ID position Before code data After code data 00 01 ...

Page 26: ...ding Ending Digits And the length is a number with two digits Code name transmission This function is to show unknown barcode symbologies that include all readable symbologies of the scanner When Enable is selected Code Name will be transmitted before code data you will know what kind of barcode symbology is transmitted Case conversion Under the barcode you can set the alphabet in either upper cas...

Page 27: ...e 00 01 Code name transmission Disable Enable 00 01 Case conversion Disable Upper case Lower case For barcode data only 00 01 02 Format of barcode data transmission Prefix Name Preamble ID Code Length Barcode data ID Postamble Suffix Insert groups ...

Page 28: ... when no code is decoded after the Stand by duration elapsed Continuous The scanner always keeps reading and it does not matter when trigger button is pressed or duration is elapsed Double read timeout If the barcode has been scanned twice then only the first barcode will be accepted Double confirm If this is enabled the scanner will require several successful decodings to confirm the barcode data...

Page 29: ... Good read off Momentary Alternate Timeout off Continue Test only 00 01 02 03 04 05 Stand by duration 01 99 second 01 99 06 Double read timeout 01 99 10 msec 01 99 50 Double confirm 00 99 00 no double confirm 00 09 00 Supplement Check Counter 00 40 00 40 20 Program ...

Page 30: ...es of setting have no effect on certain symbologies with fixed length Notes 1 Please set the min max length if you have a special demand for individual barcode 2 Include the Check sum digits if you want to set Global min max code length Inverted image scan Set to Enabled the scanner will scan both black white barcode with white black background CTS trigger This operation enables an external device...

Page 31: ...Option Alphanumeric Entry Global min code length 00 64 00 64 04 Global max code length 00 64 00 64 63 Inverted image scan Disable Enable 00 01 CTS trigger Disable Enable 00 01 Stand mode selection LED on LED off 00 01 Program ...

Page 32: ...digits Prefix Data Digits Suffix Suffix characters Up to 22 ASCII characters may be sent after data digits Option Bar Code Option Alphanumeric Entry Prefix characters setting None 1 22 characters 00 00 ffH ASCII code Suffix characters setting None 1 22 characters 0D 00 ffH ASCII code Program ...

Page 33: ...rcode on the fold out page 5 Scan Exit barcode Insert G1 G2 G3 G4 character setting The scanner offers 4 positions and 4 characters to insert among the symbol Example Barcode 1 2 3 4 5 6 Output Barcode 1 2 A B 3 4 C D 5 6 Steps 1 Scan Programming and Insert G1 characters setting barcode 2 Use the ASCII code table to find the value of A 41 B 42 3 Scan 4 1 and 4 2 from the barcode on the fold out ba...

Page 34: ...racters None 1 22 characters POSTAMBLE 00 ffH ASCII code Insert G1 characters None 1 22 characters GROUP1 00 ffH ASCII code Insert G2 characters None 1 22 characters GROUP2 00 ffH ASCII code Insert G3 characters None 1 22 characters GROUP3 00 ffH ASCII code Insert G4 characters None 1 22 characters GROUP4 00 ffH ASCII code Program ...

Page 35: ...ng The maximum value of truncate digits is 15 Code ID setting Code ID setting is a character used to represent the symbol upon a successful read A Code ID setting is added to the transmitted data at the beginning or end if this feature is selected If you want the application to transmit Code ID you must set Code ID transmission to Enable first Refer to Code ID transmission Insertion group selectio...

Page 36: ...hanumeric Entry Read Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH A Insert group selection 00 44 00 44 00 Program ...

Page 37: ...igits Check Digit Supplement Digits 2 or 5 or UCC EAN 128 Truncation Expansion The leading 0 digits of UPC A data characters can be truncated when enabled Supplement Check Counter It will be more reliable to read the barcode with the extension supplement like UPC E A or EAN 8 13 but it will slow down the decoding speed when this counter is set ...

Page 38: ...ric Entry Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All 00 01 02 03 04 05 06 07 Truncation Expansion None Truncate leading zero Expand to EAN13 00 01 02 Supplement Check Counter 20 The Program ...

Page 39: ... as the sum of the numerical value of the data digits Check sum transmission By setting Enable checks sum will be transmitted Truncate leading ending Refer to Truncate leading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Leading Zero Data Digits 6 Digits Check Digits ...

Page 40: ...Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH E Program ...

Page 41: ...on function is used only for UPC E and EAN 8 code reading It extends to 13 digits with 0 digits when the feature is enabled Example Barcode 0123654 Output 0012360000057 UPC E 1 To enable scanner to read UPC E with leading digit Supplement Check Counter It will be more reliable to read the barcode with extension supplement for UPC E A or EAN 8 13 but it will slow down the decoding speed when this c...

Page 42: ... 00 Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All 00 01 02 03 04 05 06 07 Truncation Expansion None Truncate leading zero Expand to EAN13 Expand to UPCA 00 01 02 03 Expansion Disable Enable 00 01 UPCE 1 Disable Enable 00 01 Program ...

Page 43: ...42 Exit Supplement Check Counter 20 ...

Page 44: ... of the numerical value of the data digits Check sum transmission By setting Enable checks sum will be transmitted Truncate leading ending Refer to Truncate leading ending of UPC A The Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Truncate leading 0 15 00 15 00 Program ...

Page 45: ...44 Exit Truncate ending 0 15 00 15 00 ...

Page 46: ...er are two kinds of barcodes for book and magazines The ISBN is 10 digits with leading 978 and the ISSN is 8 digits with leading 977 of the EAN 13 symbology Example Barcode 9789572222720 Output 9572222724 Example Barcode 9771019248004 Output 10192484 Supplement Check Counter It will be more reliable to read the barcode with extension supplement for UPCE A or EAN 8 13 but it will slow down the deco...

Page 47: ...oup selection 00 44 00 44 00 Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All 00 01 02 03 04 05 06 07 ISBN ISSN conversion Disable Enable 00 01 Supplement Check Counter 20 ...

Page 48: ...Check sum transmission By setting Enable checks sum will be transmitted Truncate leading ending Refer to Truncate leading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Program ...

Page 49: ...48 Exit Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting Two characters 00 ffH ASCII code 00 ffH 00 ffH FF Insert group selection 00 44 00 44 00 ...

Page 50: ...o Expansion of UPC E Supplement Check Counter It will be more reliable to read the barcode with extension supplement for UPC E A or EAN 8 13 but it will slow down the decoding speed when this counter is set Option Bar Code Option Alphanumeric Entry Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All 00 01 02 03 04 05 06 07 Counter 20 Program ...

Page 51: ...50 Exit Truncation Expansion Disable Enable 00 01 Truncation Expansion None Truncate leading zero Expand to EAN13 00 01 02 Expansion Disable Enable 00 01 ...

Page 52: ...length is defined as to the actual barcode data length to be sent Label with length exceeds these limits will be rejected Make sure that the Minimum length setting is no greater than the Maximum length setting or otherwise all the labels of the symbology will not be readable In particular you can see the same value for both Minimum and Maximum reading length to force the fixed length barcode decod...

Page 53: ...n Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 01 Truncate leading 0 20 00 20 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH ...

Page 54: ... code space for Code 39 If Enable and other symbols were read again with the appended code then codes will be transmitted without Code ID Preamble and Prefix When a symbol is decoded without the appended code the data will be transmitted without Code ID and Prefix but the Postamble Suffix codes are appended This function is used when the first number of Code 39 is a space Example 123456 Start end ...

Page 55: ...54 Exit Format Standard Full ASCII 00 01 Append Disable Enable 00 01 Start end transmission Disable Enable 00 01 ...

Page 56: ...setting Enable checksum will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum verification Disable Enable 00 0...

Page 57: ...on Disable Enable 00 01 Max code leading 00 64 00 64 00 Min code leading 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH i Insert group selection 00 44 00 44 00 ...

Page 58: ...e 39 Truncate leading ending Refer to Truncate leading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Program ...

Page 59: ...58 Exit Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH i Insert group selection 00 44 00 44 00 ...

Page 60: ...le checksum will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Verification Disable Enable 00 01 Disable Ena...

Page 61: ... Transmission Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH B Insert group selection 00 44 00 44 00 ...

Page 62: ...checksum will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Verification Disable Enable 00 01 Start Data Digits Variable Checksum Optional End Program ...

Page 63: ...t Checksum Transmission Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH ...

Page 64: ...Start End pattern you may select one pair to match your application Start End Transmission Refer to Start End Transmission of Code 39 Option Bar Code Option Alphanumeric Entry Insert group selection 00 44 00 44 00 Start End type ABCD ABCD abcd abcd ABCD TN E abcd tn e 00 01 02 03 Start End transmission Disable Enable 00 01 Program ...

Page 65: ...The checksum is made as the sum module 103 of all data digits Checksum Transmission By setting Enable checksum will be transmitted Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Verification Disable Enable 00 01 Checksum Transmission Disable Enable 00 01 Program ...

Page 66: ... selection Refer to Insertion group selection of UPC A Format The Code 128 can be translated to UCC EAN 128 format if it starts with FNC1 character The first FNC1 will be translated to C1 and next to be a field separator code as GS 1D16 C1 Data GS Data Checksum Option Bar Code Option Alphanumeric Entry Max code length 00 64 00 64 00 Min code length 00 64 00 64 01 Truncate leading 0 15 00 15 00 Pro...

Page 67: ...66 Exit Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group selection 00 44 00 44 00 Format Standard UCC EAN 128 00 01 ...

Page 68: ...etting To setting the code ID for UCC EAN 128 output format Field separator code This feature is only used for UCC EAN 128 format This Field separator code means you can reassign second or after a FNC1 for your usage The default of ASCII code is GS 1D16 Option Bar Code Option Alphanumeric Entry Append Disable Enable 00 01 UCC EAN 128 ID setting 00 ffH ASCII code 00 ffH Field separator code 00 ffH ...

Page 69: ...ksum is made as the sum module 47 of the numerical values of all data digits Checksum Transmission By setting Enable checksum will be transmitted Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Verification Disable Enable two digits 00 01 Checksum Transmission Disable Enable 00 01 Program ...

Page 70: ...eading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Option Bar Code Option Alphanumeric Entry Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Program ...

Page 71: ...70 Exit Code ID setting 00 ffH ASCII code 00 ffH Insert group selection 00 44 00 44 00 ...

Page 72: ...r selected checksum verification method Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Verification Disable One digit Two di...

Page 73: ...it Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH O Insert group selection 00 44 00 44 00 ...

Page 74: ...gits Checksum Transmission By setting Enable checksum1 and checksum2 will be transmitted upon your selected checksum verification method Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Option Bar Code O...

Page 75: ...sion Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group selection 00 44 00 44 00 ...

Page 76: ...ts Checksum Transmission By setting Enable checksum will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Verif...

Page 77: ...sion Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group selection 00 44 00 44 00 ...

Page 78: ...nsmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Checksum Verification Disable Enable 00 01 Checksum Transmission Disable Enab...

Page 79: ... 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH S Insert group selection 00 44 00 44 00 Format Numeric only Full ASCII only 00 01 ...

Page 80: ... will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Check sum verification Disable Enable 00 01 Check sum transmissio...

Page 81: ...it Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH i Insert group selection 00 44 00 44 00 ...

Page 82: ...tion group selection Refer to Insertion group selection of UPC A UCC EAN 128 emulation Refer to Transmission Code ID transmission must be set as AIM ID enable Then C1 will be identified as prefix of barcode data transmission Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH R4 Pr...

Page 83: ...82 Exit Insert group selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00 01 ...

Page 84: ... Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A UCC EAN 128 emulation Refer to UCC EAN 128 emulation of GS1 DATABAR OMNIDIRECTIONAL Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Program ...

Page 85: ...84 Exit Code ID setting 00 ffH ASCII code 00 ffH RL Insert group selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00 01 ...

Page 86: ...ding Refer to Truncate leading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A UCC EAN 128 emulation Refer to UCC EAN 128 emulation of GS1 DATABAR OMNIDIRECTIONAL Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Max code length 00 99 00 99 99 Program ...

Page 87: ... code length 00 99 00 99 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH RX Insert group selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00 01 ...

Page 88: ...9 Truncate leading ending Refer to Truncate leading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Max code length 00 64 00 64 11 Min code length 00 64 00 64 11 Program ...

Page 89: ...88 Exit Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH t Insert group selection 00 44 01 44 00 ...

Page 90: ...r to Truncate leading ending of UPC A Code ID setting Refer to Code ID setting of UPC A Insertion group selection Refer to Insertion group selection of UPC A Leading A If this function is enabled each prefix of data shall be A Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Max code length 00 64 00 64 12 Min code length 00 64 00 64 09 Program ...

Page 91: ...90 Exit Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 01 ffH p Insert group selection 00 44 00 44 00 Leading A Disable Enable 00 01 ...

Page 92: ...91 Test Chart CODABAR CODE 11 CODE 128 CODE 39 CODE 93 EAN 13 ...

Page 93: ...92 STANDARD 25 EAN 8 INDUSTRIAL 2 OF 5 UPC E INTERLEAVED 2 OF 5 ...

Page 94: ...93 MATRIX 25 MSI PLESSEY UPC A UK PLESSEY RSS ...

Page 95: ...F5 ENQ NAK 6 PgDn F6 ACK SYN 7 F7 BEL ETB 8 Bs F8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US L H 2 3 4 5 6 7 0 SP 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O _ o DEL ...

Page 96: ...r code Unique parameter list If you wish to display the unique parameter setting list scan the unique parameter list bar code System parameter setting list If you wish to display the product information and revision number for your ValueScan II scanner over the host terminal computer scan the System parameter setting list bar code String setting list If you wish to display the string format list s...

Page 97: ...u wish to display the firmware version scan the Firmware version list WARNING Default value initialization If you wish to return the ValueScan II scanner to all the factory default settings scan the Default value initialization bar code ...

Page 98: ...97 0 1 2 3 4 5 6 7 8 9 A B C Finish F E D ...

Reviews: