139
SET (Setting) Mode
Section 6-1
Set the various reading condition parameters. This menu can also be
used to view or change parameters set using the teaching function.
Note
“Length of Finder” is the length of the finder patterns for the code
expressed in pixel units. The V530-R150 detects finder patterns
that correspond to this length and performs readings. “Free
Finder Length” is a function that is used when there are several
different sizes of reading codes, with large differences in the
length of the finder. If this function is turned ON, any finder pat-
terns as long as or longer than the value set as the “Length of
Finder” will be detected and reading performed.
1,2,3...
1.
Select the color of symbol.
1. Read DM (Normal)
Reading Settings (Manual)
*: Indicates items set automatically using the teaching function.
Black
(Default
setting)
White
Auto
Automatically determines the appropriate symbol color.
Use this setting when reading codes that include both
symbol colors. If, however, the symbol color is known to be
one or the other (i.e., either black or white), set to black or
white to reduce the required processing time.
Black symbol printed on white base.
White symbol printed on black
base.
Summary of Contents for V530-R150E-3 -
Page 7: ......
Page 9: ......
Page 17: ......
Page 27: ......
Page 47: ......
Page 63: ......
Page 224: ...207 System Section 6 4 2 Set each item 3 Select End before leaving this screen...
Page 226: ...209 System Section 6 4 2 Select the error method 3 Select End to leave this screen...
Page 263: ......
Page 279: ......
Page 281: ......
Page 283: ......
Page 289: ......