96
Connection Examples
Section 4-5
Cable Wiring
Connection 1
The wiring required between V530-R150s and NT-AL001s is shown
below.
Connection 2
The wiring required between NT-AL001s is shown below.
Connection 3
The wiring required between the NT-AL001 on the host side and the
NT-AL001 on the V530-R150 side is shown below.
V530-R150
NT-AL001
Signal
SD (TXD)
RD (RXD)
RS (RTS)
CS (CTS)
SG (GND)
Pin No.
2
3
4
5
9
Meaning
Send data
Receive data
Request to send
Clear to send
Power supply (+5 V)
Signal ground
5 V
power
supply
Pin No.
2
3
4
5
6
9
Signal
SD (TXD)
RD (RXD)
RS (RTS)
CS (CTS)
+5 V
SG (GND)
NT-AL001
NT-AL001
Signal
SG (GND)
SDB
SDA
RDB
RDA
Pin No.
2
3
4
5
6
Pin No.
2
3
4
5
6
Signal
SG (GND)
SDB
SDA
RDB
RDA
NT-AL001 on host side
NT-AL001 on V530-R150 side
Signal
SG (GND)
SDB
SDA
RDB
RDA
Pin No.
2
3
4
5
6
Pin No.
2
3
4
5
6
Signal
SG (GND)
SDB
SDA
RDB
RDA