41
Timing Chart
Section 3-3
3-3-3
Reading Level Trigger (when trigger mode is “Level
Trigger”)
OK judgment (Readable)
Note
The output time to RS-232C changes according to the data vol-
ume and baud rate.
Output Terminals
The same as continuous mode.
Input Terminals
Enter RUN mode
Leave RUN mode
RUN
TRIG B
BUSY
OK/NG
DO 0 to 3
GATE
(RS-232C)
Reading (OK)
Judgment (OK)
Coincidence judgment
Gate ON delay Gate ON time
Output period
*Delay of 33.3 ms max. occurs before starting to
load images after TRIG B signal is turned ON.
Terminal
Function
TRIG B
Continuous reading is performed while TRIG B signal is turned ON until OK
(readable) reading judgment is output.