255
Error Codes and Countermeasures
Section 9-2
9-2-2
Data Matrix Reading in Pattern Mode
Error Code
Description
Countermeasures
E160
Timing pattern detec-
tion error 1 (No finder
patterns were detected
for models 1 or 2)
No timing pattern was detected.
• The timing pattern may be stained or damaged. Check
the condition of the timing pattern.
• The correlation value may be too high. Decrease the
correlation value.
• A model may not be registered. Confirm that a model is
registered.
• A model may have been registered with an incorrect
code size. Re-register the model.
E161
Timing pattern detec-
tion error 2 (32 or more
finder patterns were
detected for models 1
or 2)
Too many timing patterns (32 or more) were detected.
• The correlation value may be too low. Increase the cor-
relation value.
E170
Finder pattern detec-
tion error 1 (No finder
pattern was detected
for model ABC)
No finder pattern was detected.
• The finder pattern may be stained or damaged. Check
the condition of the finder pattern.
• The correlation threshold value may be too high.
Decrease the correlation value.
• A model may not be registered. Confirm that a model is
registered.
• A model may have been registered with an incorrect
Matrix size. Re-register the model.
• Model registration may not have been performed in the
optimum way. Re-register the model with reference to
page 152.
E171
Finder pattern detec-
tion error 2 (32 or more
finder patterns were
detected for model
ABC)
Too many finder patterns (32 or more) were detected.
• The correlation threshold value may be too low.
Increase the correlation value.
• Model registration may not have been performed in the
optimum way. Re-register the model with reference to
page 152.
E172
Finder pattern detec-
tion error 3 (Relative
positioning is incorrect
for model ABC)
3 points of the finder pattern were detected.
However, the relative positioning of the patterns is incor-
rect.
• The finder pattern may be stained or damaged. Check
the condition of the finder pattern.
• The correlation threshold value may be too high.
Decrease the correlation value.
• Model registration may not have been performed in the
optimum way. Re-register the model with reference to
page 152.
Summary of Contents for V530-R150E-3 -
Page 7: ......
Page 9: ......
Page 17: ......
Page 27: ......
Page 47: ......
Page 63: ......
Page 224: ...207 System Section 6 4 2 Set each item 3 Select End before leaving this screen...
Page 226: ...209 System Section 6 4 2 Select the error method 3 Select End to leave this screen...
Page 263: ......
Page 279: ......
Page 281: ......
Page 283: ......
Page 289: ......