190
MON (Monitor) Mode
Section 6-2
When Data History is ON:
The number of readings and the number of OK readings recorded
since this setting was turned ON, and error count results are dis-
played. To reset Data History, set to OFF and select Register. Turn
OFF Judge Coincidence and Reading Accuracy functions because
they cannot be used together with Data History.
When Reading Accuracy is ON:
Ten readings are performed with one trigger and the result is dis-
played.
The reading accuracy cannot be counted for the continuous reading
commands. The most recent error code will be displayed if the Read-
ing Accuracy is 0%.
Turn OFF the Judge Coincidence and Data History functions
because they cannot be used together with the Reading Accuracy
function.
Reading data
Error code
Number of
occurrences
Reading data
Error code
Number of
occurrences