170
SET (Setting) Mode
Section 6-1
After changing the setting, perform a search to confirm whether
the search can be performed correctly.
5.
Set the correlation threshold value for detecting finder patterns.
Correlation values equal to or higher than the threshold are de-
tected. (Setting range: 1 to 100; default setting: 30.)
6.
Set the timeout time for decode processing of a single image
read. (Setting range: 200 to 2,000 ms; default setting: 500 ms.)
7.
Select the number of times reading is repeated in the event of in-
correct reading. A fresh image will be obtained and reading per-
formed for the number of times specified. (Setting range: 0 to 9
times; default setting: 0.)
Note
If Display Settings/Finder Pattern is set to ON, whether finder
patterns can be detected or not can be confirmed on the screen.
page 142
• If nothing is detected, decrease the correlation threshold val-
ue and the pixel skipping parameter and check the model im-
age.
• If too many places are detected, increase the correlation val-
ue and pixel skipping parameter.
Procedure
1,2,3...
1.
Select Read QR (Pattern).
Pixel Skipping X
Pixel Skipping Y
Set the number of pixels
skipped when searching.