117
Introduction
Section 6-1
2.
With the message service, there is no guarantee that a message to a re-
mote node will reach its destination. It is always possible that the message
may be lost in transit due to noise or some other condition. When using the
message service, it is advisable to prevent this situation from occurring by
performing resend processing at the node where instructions are issued.
With the SEND, RECV, and CMND instructions, resend processing is per-
formed automatically once the number of retries has been set, so be sure
to specify a number other than “0” for the number of retries.
Example: Commands for
CVM1, CV-series and CS-
series PLCs
Type of command
Code
CS
CVM1/
CV
For memory areas (CIO,
DM, EM, TC, transition,
step, forced ON/OFF)
MEMORY AREA READ
0101
Yes
Yes
MEMORY AREA WRITE
0102
Yes
Yes
MEMORY AREA FILL
0103
Yes
Yes
MULTIPLE MEMORY
AREA READ
0104
Yes
Yes
MEMORY AREA
TRANSFER
0105
Yes
Yes
For parameter areas (PLC
system setting, I/O table
registration, routing table,
etc.)
PARAMETER AREA
READ
0201
Yes
Yes
PARAMETER AREA
WRITE
0202
Yes
Yes
PARAMETER AREA
CLEAR
0203
Yes
Yes
For program areas (UM)
PROGRAM AREA PRO-
TECT
0304
Yes
Yes
PROGRAM AREA PRO-
TECT CLEAR
0305
Yes
Yes
PROGRAM AREA READ 0306
Yes
Yes
PROGRAM AREA
WRITE
0307
Yes
Yes
PROGRAM AREA
CLEAR
0308
Yes
Yes
PLC mode
RUN
0401
Yes
Yes
STOP
0402
Yes
Yes
PLC model data
CONTROLLER DATA
READ
0501
Yes
Yes
CONNECTION DATA
READ
0502
Yes
Yes
PLC status data
CONTROLLER STATUS
READ
0601
Yes
Yes
CYCLE TIME READ
0620
Yes
Yes
PLC internal clock
CLOCK READ
0701
Yes
Yes
CLOCK WRITE
0702
Yes
Yes
Messages
MESSAGE READ
0920
Yes
Yes
MESSAGE CLEAR
Yes
Yes
FAL/FALS READ
Yes
Yes
Access rights
ACCESS RIGHT
ACQUIRE
0C01
Yes
Yes
ACCESS RIGHT
FORCED ACQUIRE
0C02
Yes
Yes
ACCESS RIGHT
RELEASE
0C03
Yes
Yes
Summary of Contents for CS1W-CLK12-V1
Page 3: ...iv ...
Page 5: ...vi ...
Page 9: ...x TABLE OF CONTENTS ...
Page 11: ...xii ...
Page 59: ...42 Component Names and Functions Section 3 1 Dimensions Unit mm ...
Page 62: ...45 Component Names and Functions Section 3 1 Dimensions Unit mm ...
Page 91: ...74 CVM1 and CV series Optical Ring Controller Link Units Section 4 2 ...
Page 108: ...91 Setting Data Links Section 5 2 Device Information Setting Data Link Tables ...
Page 125: ...108 Checking Data Link Status Section 5 4 ...
Page 181: ...164 Setting Routing Tables Section 7 4 ...
Page 199: ...182 Memory Areas Related to Duplex Operation Section 8 6 ...
Page 275: ...258 Handling Precautions Section 10 7 ...
Page 298: ...281 CS series Optical Bus Controller Link Units Appendix C Dimensions Unit mm 101 35 130 ...
Page 299: ...282 CS series Optical Bus Controller Link Units Appendix C ...