Conformance to EC Directives
6
standards in the system used by the customer, however, must be checked by
the customer.
EMC-related performance of the OMRON devices that comply with EC Direc-
tives will vary depending on the configuration, wiring, and other conditions of
the equipment or control panel on which the OMRON devices are installed.
The customer must, therefore, perform the final check to confirm that devices
and the overall machine conform to EMC standards.
Note Applicable EMC (Electro-Magnetic Compatibility) standards are as follows:
EMS (Electro-Magnetic Susceptibility):
EN61131-2 for CVM1 and CV Series
EN61000-6-2 for CS Series
EMI (Electro-Magnetic Interference):
EN50081-2
(Radiated emission: 10-m regulations)
The Controller Link Units that comply with EC Directives (CVM1-CLK12,
CVM1-CLK52, CS1W-CLK11, CS1W-CLK12, CS1W-CLK12-V1, CS1W-
CLK52, and CS1W-CLK52-V1) must be installed as follows:
1,2,3...
1.
The Controller Link Units are designed for installation inside control pan-
els. All Controller Link Units must be installed within control panels. Use
the following or equivalent control panels: CVM1-CLK12/52: SA20-614 by
NITTO Electric Words, Ltd., CS1W-CLK11/12/12-V1/52/52-V1: SA20-712
by NITTO Electric Words, Ltd.
2.
Use reinforced insulation or double insulation for the DC power supplies
used for the communications power supply and I/O power supplies.
3.
The Controller Link Units that comply with EC Directives also conform to
the Common Emission Standard (EN50081-2). Radiated emission charac-
teristics (10-m regulations) may vary depending on the configuration of the
control panel used, other devices connected to the control panel, wiring,
and other conditions. You must therefore confirm that the overall machine
or equipment complies with EC Directives.
4.
The CS1W-CLK52/CLK52-V1 conforms to the Emission Standard
(EN61000-6-2) for EMS but, depending on the backup power supply used,
they may not conform to the standard for immunity to surges (IEC61000-
4-5). In order to ensure conformance, either use an OMRON S82K-series
power supply, which is the recommended backup power supply, or take
surge countermeasures at the primary side.
Summary of Contents for CS1W-CLK12-V1
Page 3: ...iv ...
Page 5: ...vi ...
Page 9: ...x TABLE OF CONTENTS ...
Page 11: ...xii ...
Page 59: ...42 Component Names and Functions Section 3 1 Dimensions Unit mm ...
Page 62: ...45 Component Names and Functions Section 3 1 Dimensions Unit mm ...
Page 91: ...74 CVM1 and CV series Optical Ring Controller Link Units Section 4 2 ...
Page 108: ...91 Setting Data Links Section 5 2 Device Information Setting Data Link Tables ...
Page 125: ...108 Checking Data Link Status Section 5 4 ...
Page 181: ...164 Setting Routing Tables Section 7 4 ...
Page 199: ...182 Memory Areas Related to Duplex Operation Section 8 6 ...
Page 275: ...258 Handling Precautions Section 10 7 ...
Page 298: ...281 CS series Optical Bus Controller Link Units Appendix C Dimensions Unit mm 101 35 130 ...
Page 299: ...282 CS series Optical Bus Controller Link Units Appendix C ...