49
Installing Slave Units
Section 3-1
• Units with MIL Connectors (CRT1-V
@
D32ML(-1))
Horizontal Mounting to a
Wall
• Units with e-CON Connectors (CRT1-V
@
D08S(-1)) or MIL Connectors
(CRT1-V
@
D16ML(-1))
• Units with MIL Connectors (CRT1-V
@
D32ML(-1))
3-1-5
Mounting with Screws
Refer to the dimensions for the particular Unit and prepare the mounting holes
in the panel. Tighten the M4 screws to a torque of 0.9 N·m, and check to be
sure that the Unit is securely mounted.
3.3
45
35
(mm)
Mounting Bracket
2.45
45
45
Mounting
Bracket
(mm)
(The Unit shown in the diagram is the CRT1-V
@
D08S(-1).)
0.1
45
35
Mounting
Bracket
(mm)