90
Connecting External I/O for Slave Units
Section 3-6
OMRON Connectors
■
Preparing External Device Cables
Using Tyco Electronics or Sumitomo 3M Connectors
The sensor and other external device cables for connector output with transis-
tors are normally either semi-stripped or stripped, as shown in the following
diagram.
When the cables are prepared this way, a cable connector cannot be
attached, so first cut the end and remove the cable sheath as shown in the fol-
lowing diagram. (Do not strip the sheaths of the core wires.)
Using OMRON Connectors
Align the cable with the strip gauge on the side of the connector. Remove 7 to
8 mm of the wiring sheath, and twist the exposed wires several times.
■
Inserting Cable Wires into the Cable Connector
Insert the cable wires of the external device into the cable connector, and con-
nect each wire so that the terminal number on the connector cover matches
the wire color as shown in the following table.
37104-2124-000FL
Green
AWG22 (0.3 mm
2
) to AWG20 (0.5 mm
2
),
sheath outer diameter: 1.0 to 1.2 mm
37104-2165-000FL
Blue
AWG22 (0.3 mm
2
) to AWG20 (0.5 mm
2
),
sheath outer diameter: 1.2 to 1.6 mm
37104-2206-000FL
Gray
AWG22 (0.3 mm
2
) to AWG20 (0.5 mm
2
),
sheath outer diameter: 1.6 to 2.0 mm
Model
Specification
Applicable wire range
XN2A-1430
Spring clamp type AWG28 (0.08 mm
2
) to AWG20 (0.5 mm
2
),
sheath outer diameter: 1.5 mm max.
Model
Housing color
Applicable wire range
Semi-stripped cable
Stripped cable
20 mm min.
7 to 8 mm
Terminal
number
Using CRT1-VID08S, CRT1-
ID16S(H), CRT1-MD16S(H), CRT1-
ID32S(H), CRT1-MD32S(H),
CRT1B-ID02S, CRT1B-ID02SP,
CRT1B-ID04SP
Using CRT1-VID08S-1, CRT1-
ID16S(H)-1, CRT1-MD16S(H)-1,
CRT1-ID32S(H)-1, CRT1-
MD32S(H)-1, CRT1B-ID02S-1,
CRT1B-ID02SP-1, CRT1B-
ID04SLP-1
3-wire sensor
(without self-
diagnostic
output)
2-wire sensor
(without self-
diagnostic
output)
3-wire sensor
(without self-
diagnostic
output)
2-wire sensor
(without self-
diagnostic
output)
1
Brown (red)
---
Brown (red)
Brown (white)
2
---
---
---
---
Summary of Contents for CRT1 - 10-2008
Page 2: ...CRT1 Series CompoNet Slave Units and Repeater Unit Operation Manual Revised October 2008...
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi...
Page 23: ...xxiv Conformance to EC Directives 6...
Page 51: ...28 Slave Unit Models Section 1 2...
Page 123: ...100 Connecting External I O for Slave Units Section 3 6...
Page 365: ...342 Temperature Input Units Section 7 5...
Page 381: ...358 Expansion Unit Specifications Section 8 2...
Page 418: ...395 Repeater Unit Section 10 2 Dimensions 42 3 50 3 1 27 5 95 mm...
Page 419: ...396 Repeater Unit Section 10 2...
Page 424: ...401 CX Integrator Section 11 1...
Page 575: ...552 Current Consumption Summary Appendix D 552...
Page 581: ...558 Index...
Page 583: ...560 Revision History...