Functions Unique to Bit Slave Units
Section 11-6
Note
The OMRON S82J-series Power Supply Unit is recommended as the I/O
power supply. Load short-circuits may not be detected for power supplies with
an inverted L overcurrent protection characteristic. If using a power supply
with an inverted L overcurrent protection characteristic, use one rated for
100 W or higher.
Checking Using the CX-Integrator
1,2,3...
1.
Turn ON the power supply to the CompoNet Slave Unit.
2.
Switch to the Online Window, and then right-click the icon for the desired
CompoNet Slave Unit in the Network Configuration Window and select
Monitor
from the pop-up menu.
3.
Make sure that the
External Load Short-circuit Protection
Check Box is se-
lected.
4.
Click the
Close
Button and exit the window.