7-6 Editing Master Unit Parameters
7-6-1 Master Unit Parameter Settings
7-22
Software Setting Table Tab Page
Name
Function
Word OUT
Word IN
Bit OUT
Data
Bit IN
Used to set the memory areas from which words will
be allocated to the Slave Units. You can select from
the CIO, WR, HR, and DM Areas. Also used to set the
addresses of the first words to allocate and the
numbers of nodes to which words will be allocated.
Word Slave Status
Participation and
Communications
Error Flags
Bit Slave Status
Used to set the memory areas from which words will
be allocated to the Error Flags. You can select from
the CIO, WR, HR, and DM Areas. Also used to set the
address of the first word to allocate.
Default Setup
Returns the set values to their default settings.