2-1 Basic
Procedures
2-4
Note
1. A local network table must be registered in the CPU Unit when the target PLC has
more than one Network Communications Unit, except in the case outlined below.
Even if an online connection is made to a PLC, it will not be possible to upload or
download the network configurations unless a local network table is registered.
2. When any other tools are connected via the USB port in a CJ2-series CPU Unit,
make the tools offline, and then connect CX-Integrator online.
Note
The following case is an exception to the rule that a local network table must be regis-
tered if there are two or more Network Communications Units mounted.
Overview:
If a local network table is not registered and a direct serial connection is
made to a target PLC in which two or more Network Communications
Units are mounted, it will be possible to access only the network of the
Communications Unit with the lowest unit number.
In this case, the network address of each network will be 0 and the
network addresses will be displayed as “
−
” in the Online Connection
Information Window.
Procedure: Connect online to the relay PLC. Open the Online Connection
Information Window and right-click the Network Communications Unit
with the lowest unit number and select
Connect
from the pop-up menu.
That Network Communication Unit’s network is the only network that will
be accessible.
Computer running CX-Integrator
CS/CJ-series PLC
Relay PLC (= target PLC)
Direct serial
communications
More than One Network Communications Unit (Ethernet Unit,
Controller Link Unit, SYSMAC LINK Unit, DeviceNet Unit, or FL-net
Unit)
Local Network Table Not Registered in PLC to which a Direct
Serial Connection Has Been Made:
Access is possible only to the Network Communications Unit
with the smallest unit number, which is the Controller Link Unit
in this example.
After connecting online to the relay PLC, the Network Communications Unit will
be displayed in the Online Connection Information Window with the network
addresses given as “
−
”.
Right-click the Network Communications Unit with the smallest unit number and
select
Connect
from the pop-up menu to enable accessing that network.
Ethernet (network address = 0)
Controller Link (network address = 0)
Ethernet Unit’s unit number: 2
Controller Link Unit’s unit number: 1
DeviceNet (network address = 0)
DeviceNet Unit’s unit number: 3
Summary of Contents for CJ Series
Page 2: ......
Page 3: ...CXONE AL C V3 CXONE AL D V3 CX Integrator Ver 2 3 Operation Manual Revised February 2009 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 18: ...xviii ...
Page 154: ...Communications Section 3 Routing Tables This section describes how to set the routing tables ...
Page 189: ...3 3 Maintenance after Network Configuration 3 3 2 Editing the FINS Local Network Tables 3 36 ...
Page 244: ...Communications Section 5 Ethernet This section describes the operations specific to Ethernet ...
Page 249: ...5 2 Ping Test 5 2 2 Procedure 5 6 ...
Page 353: ...7 8 Other CompoNet Functions 7 8 2 Installing Expansion Modules 7 32 ...
Page 404: ...Appendices ...
Page 407: ...A 1 CPS File Management A 1 1 Description of CPS Files A 4 ...
Page 413: ......
Page 414: ......
Page 415: ......