2-2
Connecting Online to the Relay PLC
2-2-2 Procedures
2-14
Item
Contents
Device Name
Relay Device (fixed)
Series
Device Type
CPU Unit model
CS1H CS1H-CPU67/66/65/64/63(-V1)
CS1G/CJ1G CS1G-CPU45/44/43/42(-V1)
CS1G-H CS1G-CPU45H/44H/43H/42H
CS1H-H CS1H-CPU67H/66H/65H/64H/63H
CS1D-H CS1D-CPU67H/65H
CS Series
CS1D-S CS1D-CPU67S/65S/44S/42S
CJ2H CJ2H-CPU
@@
(-EIP) (See note 1.)
CS1G/CJ1G CJ1G-CPU45/44
CJ1M CJ1M-CPU23/22/21/13/12/11
CJ1G-H CJ1G-
CPU45H/44H/43H/42H,
CJ1G- CPU45P/44P/43P/42P
CJ1H-CPU67H/66H/65H
CJ Series
CJ1H-H
CJ1H-CPU67H-R/66H-R/65H-R/64H-R
CP1H-XA
@@@@
-
@
CP1H-X
@@@@
-
@
CP1H
CP1H-Y
@@@@
-
@
CP1L-M
@@@@
-
@
CP-Series
CP1L
CP1L-L
@@@@
-
@
NSJ Series
NSJ
G5D (Used for the NSJ5-TQ0
@
-G5D,
NSJ5-SQ0
@
-G5D, NSJ8-TV0
@
-G5D,
NSJ10-TV0
@
-G5D, and NSJ12-TS0
@
-G5D.)
M3D (Used for the NSJ5-TQ0
@
-M3D,
NSJ5-SQ0
@
-M3D, and NSJ8-TV0
@
-M3D.)
--- CompoWay/F
Device
Select CompoWay/F Device to connect the
computer running CX-Integrator directly as a
CompoWay/F slave using serial communications.
CS1G/CJ1G
CS1PC-PC101-DRM (CS1G-CPU45, See note 2.)
Device Type
SYSMAC
CS1 Board
CS1G-H
CS1PC-PC101H-DRM (CS1G-CPU45H, See note
2.)
Select one of the following network types.
Network type
Contents
Toolbus
Select to connect the computer with a direct serial
connection using the Toolbus protocol.
Note: The Toolbus (peripheral) protocol is faster than the
SYSMAC WAY protocol. Serial connections are
generally made using this network type.
Toolbus
(USB port)
Select to directly connect the computer to a CJ2 CPU Unit
with a USB cable. (See note 1.)
SYSMAC WAY
Select to connect the computer with a direct serial
connection using the SYSMAC WAY protocol. (See note 2.)
Note: The SYSMAC WAY protocol enables 1:N
connections, which are not possible for the Toolbus
protocol.
Ethernet
Select to connect the computer directly to an Ethernet
network using the Ethernet UDP/IP protocol. (See note 1.)
Ethernet (FINS/TCP)
Select to connect the computer directly to an Ethernet
network using the Ethernet TCP/IP protocol. (See note 1.)
FinsGateway
Select to use FinsGateway for communications. (Selected
when using FinsGateway for all communications.)
Note: If FinsGateway is selected, connection will not be
possible to a DeviceNet, CompoNet, or CompoWay/F
network.
Controller Link
Select to connect the computer directly to a Controller Link
network through a Controller Link Support Board.
SYSMAC LINK
Select to connect the computer directly to a SYSMAC LINK
network through a SYSMAC LINK Support Board.
CompoWay/F
Select to connect the computer with a direct serial
connection to a CompoWay/F slave.
USB
Select to connect the computer directly to an NSJ-series
NSJ Controller using a USB cable.
Network Type
CS1 Board
Select to connect the computer with a SYSMAC CS1
Board. (See note 3.)
Note 1:
With a CJ2H-CPU6
@
-EIP CPU Unit, connecting to an Ethernet network is not
Summary of Contents for CJ Series
Page 2: ......
Page 3: ...CXONE AL C V3 CXONE AL D V3 CX Integrator Ver 2 3 Operation Manual Revised February 2009 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 18: ...xviii ...
Page 154: ...Communications Section 3 Routing Tables This section describes how to set the routing tables ...
Page 189: ...3 3 Maintenance after Network Configuration 3 3 2 Editing the FINS Local Network Tables 3 36 ...
Page 244: ...Communications Section 5 Ethernet This section describes the operations specific to Ethernet ...
Page 249: ...5 2 Ping Test 5 2 2 Procedure 5 6 ...
Page 353: ...7 8 Other CompoNet Functions 7 8 2 Installing Expansion Modules 7 32 ...
Page 404: ...Appendices ...
Page 407: ...A 1 CPS File Management A 1 1 Description of CPS Files A 4 ...
Page 413: ......
Page 414: ......
Page 415: ......