3-2 Setting the Routing Tables
3-2-2 Creating the FINS Local Routing Tables
3-14
Input the appropriate settings in the local network tables for PLC2 and PLC3, as
shown below.
PLC2 PLC3
Local Network Table
Unit number
Local network address
4 1
5 2
Local Network Table
Unit number
Local network address
0 2
Menu Items in the PLC Routing Table Window
Main menu
Sub-menu/command
Functions
New
Initializes (clears) the FINS local routing table.
Open Local Routing Table File
Opens a FINS local routing table file (.rtg, .rxg
extension).
Save Local Routing Table File
Saves a FINS local routing table file (.rtg, .rxg
extension).
Open Network Routing Table
File
Opens a FINS network routing table file (.rt3, .rx3
extension).
File
Save Network Routing Table
File
Saves a FINS network routing table file (.rt3, .rx3
extension).
Add Remote Network
Adds a relay network table.
Edit
Add SIOU
Adds a local network table.
Always On Top
The PLC Routing Dialog Box will always be
displayed in the front of the windows.
Zoom Out
Reduces the Main View display.
Main View
Zoom In
Enlarges the Main View display.
Transfer to PLC
Transfers the edited routing tables to the PLC that is
directly connected online.
Transfer from PLC
Reads the edited routing tables from the PLC that is
directly connected online.
Delete Routing Table
Deletes the routing tables in the registered PLC that
is directly connected online.
Active Routing Table
Enables the routing tables. (See note 1.)
Deactive Routing Table
Disables the routing tables. (See note 1.)
Verify Routing Table
Compares the edited routing tables to the routing
tables in the PLC that is directly connected online.
Check Routing Table for errors
Checks the created routing tables.
Automatic Network Search
(Cannot be used.)
Switching the target PLC
(See note 2.)
Switches the target PLC to the PLC directly
connected by a serial connection, or a PLC in the
network connected to that PLC.
Number of Remote Network:
Standard [20]
Sets the maximum number of destination networks to
the standard value of 20.
Number of Remote Network:
Expanded [64]
Sets the maximum number of destination networks to
the extended value of 64.
This command is supported only for CS/CJ-series
CPU Units with unit version 4.0 or later.
Options
Show File Information
Inputs the author, title, and comment information to
be saved in the routing table file.
Help Topics
Displays help.
Help
About
Displays the Routing Table Component's version
information.
Note 1: The Enable/Disable function is supported by C-series PLCs (Controller Link) only.
Note 2: This command is supported only when connected to PLC with CS/CJ-series CPU Units
with unit version 4.0 or later.
Summary of Contents for CJ Series
Page 2: ......
Page 3: ...CXONE AL C V3 CXONE AL D V3 CX Integrator Ver 2 3 Operation Manual Revised February 2009 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 18: ...xviii ...
Page 154: ...Communications Section 3 Routing Tables This section describes how to set the routing tables ...
Page 189: ...3 3 Maintenance after Network Configuration 3 3 2 Editing the FINS Local Network Tables 3 36 ...
Page 244: ...Communications Section 5 Ethernet This section describes the operations specific to Ethernet ...
Page 249: ...5 2 Ping Test 5 2 2 Procedure 5 6 ...
Page 353: ...7 8 Other CompoNet Functions 7 8 2 Installing Expansion Modules 7 32 ...
Page 404: ...Appendices ...
Page 407: ...A 1 CPS File Management A 1 1 Description of CPS Files A 4 ...
Page 413: ......
Page 414: ......
Page 415: ......