1-2 Specifications
1-2-2
Files Created by the CX-Integrator
1-12
Item
Specification
Ethernet
Ethernet Unit settings (CPU Bus Unit System Settings)
Controller Link
SYSMAC LINK
User-set data link tables
Controller Link and SYSMAC LINK Unit settings (in allocated DM Area
words), including automatically set data link parameters (transferred to
the startup node set as the target PLC)
DeviceNet
DeviceNet Unit master parameters (remote I/O allocations, connection
settings, component information check, communications cycle time, etc.)
Slave parameters
CompoNet
CompoNet Master Unit parameters (Registration Table, message function
enable/disable, settings of Input Data Clear Mode for Communications
Errors, Manual Start Mode for remote I/O communications, Software
Setting table)
CompoNet Slave parameters
CompoWay/F
CompoWay/F slave parameters (except for Temperature Controllers)
Note: Parameters for CompoWay/F-compatible Temperature Controllers
are set using the CX-Thermo, started as an application.
PLC serial port communications settings (CPU Unit: part of PLC Setup,
Serial Communications Boards/Units: allocated DM Area words)
NT Link
None
Setting functions
FINS networks, such
as Ethernet, Controller
Link, SYSMAC LINK,
and DeviceNet
Routing tables (FINS local routing tables and FINS network routing
tables)
Note: The FINS local routing table is transferred to the target PLC.
Verification functions
Verifying communications/network configurations
Verifying component parameters
Operations
The following operations are possible for the CPU Unit at the target PLC.
Creating, editing, and transferring I/O tables
Displaying current errors and error logs
Changing the operating mode
Transferring or verifying a manually set data link table
Transferring or verifying a routing table (
FINS local routing table
)
1-2-2
Files Created by the CX-Integrator
The following files can be created by the CX-Integrator.
Files
Contents
Details
Project files (.cin)
Connection
information to relay
PLC, all network
configurations for
target PLC, and
parameters for
DeviceNet masters,
DeviceNet slaves,
CompoNet masters,
CompoNet slaves,
and CompoWay/F
slaves
These files are used offline to check network configurations and parameters
and for other purposes, such as printing. Each file consists of the following:
Device type setting information of the relay PLC
Communications Unit models connected to the target PLC (Ethernet Units,
Controller Link Units, SYSMAC LINK Units, DeviceNet Units, and Serial
Communications Boards/Units)
Device models connected to the above CPU Units or Communications
Units via communications (DeviceNet slaves, CompoNet slaves,
CompoWay/F slaves, NS-series PTs, etc.)
Parameters for DeviceNet Master Units and DeviceNet slaves (for all
devices for which EDS files are installed on the computer, including slaves
from other manufacturers)
Parameters for CompoNet Master Units and CompoNet slaves (for all
devices for which DTM is installed on the computer, including slaves from
other manufacturers)
Parameters for CompoWay/F slaves (for all components for which CPS
files are installed on the computer (except for Temperature Controllers)
Controller Link network parameters
Controller Link and SYSMAC LINK Unit allocated DM Area words settings,
including automatically set data link parameters
Ethernet Unit CPU Bus Unit System Settings
Serial Communications Board/Unit serial communications settings
Note: Routing tables (local network tables and relay network tables) and
user-set data link tables are not included in project files.
Network
configuration files
DeviceNet network
structure files (.npf)
Network configuration for one DeviceNet network connected directly to the
target PLC (including master and slave parameters)
Note: These are the same as the DeviceNet network structure files (.npf)
created with DeviceNet Configurator version 2.
@
. Files created with
DeviceNet Configurator version 2.
@
can be imported/exported.
Summary of Contents for CJ Series
Page 2: ......
Page 3: ...CXONE AL C V3 CXONE AL D V3 CX Integrator Ver 2 3 Operation Manual Revised February 2009 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 18: ...xviii ...
Page 154: ...Communications Section 3 Routing Tables This section describes how to set the routing tables ...
Page 189: ...3 3 Maintenance after Network Configuration 3 3 2 Editing the FINS Local Network Tables 3 36 ...
Page 244: ...Communications Section 5 Ethernet This section describes the operations specific to Ethernet ...
Page 249: ...5 2 Ping Test 5 2 2 Procedure 5 6 ...
Page 353: ...7 8 Other CompoNet Functions 7 8 2 Installing Expansion Modules 7 32 ...
Page 404: ...Appendices ...
Page 407: ...A 1 CPS File Management A 1 1 Description of CPS Files A 4 ...
Page 413: ......
Page 414: ......
Page 415: ......