10-2
Echoback Test between Nodes
10-2-1 Overview
10-22
10-2 Echoback Test between Nodes
10-2-1 Overview
The Internode Echoback Test between PLC Nodes tool is used to execute echoback
tests between specified networks and nodes and the CX-Integrator. Echoback tests
can be executed for Ethernet, Controller Link, SYSMAC LINK, or DeviceNet networks.
A specified data length (unit: bytes) is sent to a specified network and node. The data
is sent back as is (echoback), and the results are compared. If the data agrees, it is
judged a success. If not, it is judged a failure. This allows the communications load
conditions between the computer and specified nodes to be tested.
10-2-2 Start
Methods
Either of the following two methods can be used to start an echoback test:
Method 1: While online, open the Online Connection Information Window, right-click
the target PLC or Unit, and select
Echoback test between PLC nodes
from the
pop-up menu.
Method 2: While online, select
Tools -
Echoback test between PLC nodes
.
10-2-3 PLC Internode Echoback Test Dialog Box
The various items in the PLC Internode Echoback Test Dialog Box are explained
below.
Field
Item
Contents
Network
Input the network address. Range: 1 to 127.
Target
Node
Input the node address. Range: 1 to 254.
Data Length
Input the number of bytes of data to be sent between
nodes. Range: 1 to 256.
Times to
Repeat
Input the number of times to repeat the test.
Range: 1 to 255.
Frequency is
not specified
Check this item to repeat the tests limitlessly.
Test
Configuration
Response
wait time
Input the time to wait for the echo request packet.
Range: 1 to 30.
Network
Displays the target network address.
Node
Displays the target node address.
Connection
Model
Displays the target model.
Status Displays
the online status.
Elapsed time
Displays the time elapsed for the test.
Test Results
Tests run
Displays the number of times the test has been run.
Summary of Contents for CJ Series
Page 2: ......
Page 3: ...CXONE AL C V3 CXONE AL D V3 CX Integrator Ver 2 3 Operation Manual Revised February 2009 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 18: ...xviii ...
Page 154: ...Communications Section 3 Routing Tables This section describes how to set the routing tables ...
Page 189: ...3 3 Maintenance after Network Configuration 3 3 2 Editing the FINS Local Network Tables 3 36 ...
Page 244: ...Communications Section 5 Ethernet This section describes the operations specific to Ethernet ...
Page 249: ...5 2 Ping Test 5 2 2 Procedure 5 6 ...
Page 353: ...7 8 Other CompoNet Functions 7 8 2 Installing Expansion Modules 7 32 ...
Page 404: ...Appendices ...
Page 407: ...A 1 CPS File Management A 1 1 Description of CPS Files A 4 ...
Page 413: ......
Page 414: ......
Page 415: ......