1-5 Window
Descriptions
1-5-2 Main
Window
1-37
Communications Unit model (CPU Unit model for CPU Unit built-in serial ports)
Online Connection
Information Window
Network Address
Communications Unit name (CPU Unit for CPU Unit built-in serial ports)
Online
displayed.
Relay PLC’s CPU Unit model
Relay PLC’s FINS destination network
address
Relay PLC’s FINS destination node
address
Target PLC
displayed in green.
Note: If an online connection is
made to the relay PLC, the relay
PLC will also be the target PLC
by default.
Communications Unit and port information
for target PLC
Displayed from the top in the following order.
•
CPU ports: CPU Unit serial ports
•
Inner Boards (Nothing is displayed if no
Inner Boards are mounted.)
•
Communications Units
Target PLC
information
Unit No.
Relay PLC
communications
settings
The
icon will be displayed next to
the Communication Unit/port that is
presently connected and accessible.
Network Type
COM Port No., Baud Rate, Parity, Data
Bits, Stop Bits
Node Address
Target PLC’s CPU Unit model
Target PLC’s network address
Target PLC’s node address
Note:
If an online connection is made to the relay PLC, that PLC will be both the relay PLC and
the target PLC. The Communications Units mounted in the relay PLC will be displayed in
the Online Connection Information Window. Normally, the CX-Integrator is used with the
same PLC as both the relay PLC and the target PLC.
Once a connection has been made, it is possible to download the network configuration
and switch the target PLC to any PLC on the network. To do this, right-click a PLC on a
network and select
Connect to this PLC.
Note
CX-Integrator Communications Connections
There are three levels of CX-Integrator communications connections depending on
where the connection is made.
Summary of Contents for CJ Series
Page 2: ......
Page 3: ...CXONE AL C V3 CXONE AL D V3 CX Integrator Ver 2 3 Operation Manual Revised February 2009 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 18: ...xviii ...
Page 154: ...Communications Section 3 Routing Tables This section describes how to set the routing tables ...
Page 189: ...3 3 Maintenance after Network Configuration 3 3 2 Editing the FINS Local Network Tables 3 36 ...
Page 244: ...Communications Section 5 Ethernet This section describes the operations specific to Ethernet ...
Page 249: ...5 2 Ping Test 5 2 2 Procedure 5 6 ...
Page 353: ...7 8 Other CompoNet Functions 7 8 2 Installing Expansion Modules 7 32 ...
Page 404: ...Appendices ...
Page 407: ...A 1 CPS File Management A 1 1 Description of CPS Files A 4 ...
Page 413: ......
Page 414: ......
Page 415: ......