![Novexx AP 5.4 Gen II User Manual Download Page 86](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055086.webp)
01/12 Rev. 5.07-01
USER MANUAL
Setup
AP 5.4 – AP 5.6
18
Print contrast
The setting of the print contrast is done in the parameter menu with
SYSTEM PARAMETER > Print contrast
or, in online mode, by pressing the Prog but-
ton.
AP5.6: Due to certain limitations in operating conditions, the maximum
setable print contrast value of the AP 5.6 is limited by the following two factors:
•
Printhead reslution
•
Print speed
Parameters for
Dispenser Mode
Setting only for AP 5.4/AP 5.6 “basic” dispenser and for AP 5.4/AP 5.6 “pe-
ripheral” dispenser.
Parameters for
Rewinding Mode
Setting only for AP 5.4/AP 5.6 “basic” dispenser and for AP 5.4/AP 5.6 “pe-
ripheral” dispenser.
CAUTION!
The maximum achievable print width of the AP 5.6 is limited by print speed
and print contrast.
Pay attention to the limitations, see
Print width limitations at AP 5.6
on
page 16.
Print speed
Max. print contrast
51mm/s (2 inch/s)
120%
76mm/s (3inch/s)
117%
102mm/s (4inch/s)
115%
127mm/s (5inch/s)
100%
152mm/s (6inch/s)
85%
178mm/s (7inch/s)
76%
203mm/s (8inch/s)
67%
[Tab. 2] Max. setable print contrast with 203 dpi print heads (AP 5.6).
Print speed
Max. print contrast
<= 76mm/s (3inch/s)
120%
102mm/s (4inch/s)
105%
127mm/s (5inch/s)
88%
152mm/s (6inch/s)
74%
[Tab. 3] Max. setable print contrast with 300 dpi print heads (AP 5.6).
Parameter
Function
SYSTEM PARAMETER > Periph. device
Set to “Dispenser”
Parameter
Function
SYSTEM PARAMETER > Periph. device
Set to “Intern rewinder”.
REWINDER PARA > Rewind. direction
Select the direction of rotation (print-