![Novexx AP 5.4 Gen II User Manual Download Page 194](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055194.webp)
06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
52
WEB operator p.
(WEB operator password)
AP 5.4
AP 5.6
Only in production mode.
Modifying the password for web server access as supervisor.
Default setting: „operator“
The user name is also „operator“.
If the user logs in as operator to the web server, he/she has access to a
selection of parameters, which are necessary for settings during labelling
operation.
For details see paragraph
AP 5.4/5.6 operator parameters
on page 13.
Changing the password at the operating panel:
1. Press the Esc button. The cursor jumps to the first character.
2. Press the Cut- or Feed button until the wanted character appears.
Acknowledge by pressing the Online button.
3. Type in the next character.
4. Acknowledge the new password by pressing the Online button.
Alternatively, the password can be typed in using a keyboard, or via the
web server.
Time client
AP 5.4
AP 5.6
Loads the current time from a time server.
Off
The time client is switched off.
On
The time client is switched on. The time is loaded with the frequency set un-
der
Sync. interval
from a time server with the IP address
Time server IP
.
With the time client service, the current date and time can be obtained
from a time server using RFC868 time protocol on UDP port 37. For this
purpose, a time server IP address needs to be given. Date and time are ini-
tially requested at start up an optional in a setable update interval during op-
eration time. It is also stored in the internal real time clock. There is no time
offset or daylight saving hour, so the server time must exactly match the local
time of the printer.