06/15 Rev. 10
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
35
4100-4106
Message, which can only occur with OLV-Option
4100
No OLV data
Status
The OLV found out, that the bar code type and/or the bar code data, which
was just printed and read, doesn´t match the bar code specified in the print
job. The error may have one of the following causes:
•
OLV is not connected/switched on
•
The bar code has not been printed
•
The bar code has been printed poorly, so that the OLV can not detect it.
Measure
Check, if the OLV is connected correctly
Check the printout quality. If the printout is poor, change the print
parameters and/or use a different material/ribbon-combination.
Make a dot check. May be, that a dot is defective, which was ought to print
an important line of the bar code.
If the bar code has not been printed at all: check the print job.
4101
OLV limit exceed
Status
The read bar code exceeds a user-specified limit. The limits, e.g. contrast
or readability, can be set via the parameter menue or via Easy Plug
command.
Measure
Check the printout quality.
Change the limit.
Eventually modify the print parameters or the material/ribbon combination.
4103
OLV barcode type
Status
The OLV found out, that the bar code type, which was just printed and
read, doesn´t match the bar code specified in the print job.
Measure
Check the printout.
4104 OLV
Timeout
Status
General software error
Measure
Please read the notes in section
General software errors
.