No USI interface
Status
(DPM / PEM / ALX 92x only)
This error appears, if no USI is detected while the printer is powering up.
Measure
Check, if the USI is defective or not built in.
5151 Applic.
interf.
Applicator
interface
Status
(DPM / PEM / ALX 92x only)
Neither Applicator Interface (AI), nor USI are connected to the device.
Measure
Connect a USI or AI to the device.
5152 Winding
direct.
(ALX 92x with M5A motor output stages only)
Status
The backing paper end is not correctly attached to the rewinder mandrel.
Wrong machine type selected (
SPECIAL FUNCTION > Printer type
).
Attach the backing paper web to the rewinding mandrel as described in the
user manual.
Setting „RH“ at a LH machine or vice versa.
5200 Home
position
Status
The applicator did not reach its home position within the given time frame.
Possible
causes:
•
The applicator is jammed
•
Applicators driven by compressed air: The air supply may be interrupted or
switched off
•
Cable not connected properly
Measure
Check cable and compressed air connections; reconnect them properly, if
necessary.
May the applicator move unhindered? – remove any obstacles.
5201 Touch
down
Status
The applicator did not reach its touch down position within the given time
frame.
Measure
Check cable and compressed air connections; reconnect them properly, if
necessary.
May the applicator move unhindered? – remove any obstacles.
5203
Touch down sens.
Status
The touchdown sensor(s) was/were already triggered before the
application.
Measure
Check cable and compressed air connections; reconnect them properly, if
necessary.