![Novexx AP 5.4 Gen II User Manual Download Page 198](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055198.webp)
06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
56
SYSTEM PARAMETER
Foil end warning
AP 5.4
AP 5.6
Setting of a limit diameter for the ribbon roll. If the ribbon roll diameter falls
below the set value, the displayed message changes from…
For details refer to the parameters
DP INTERFACE > Ribbon signal
and
SERVICE DATA > OPERATION DATA > Foil diameter
x.xx mm
Setting range: 25.4 to 50.0 mm; Unit interval: 0.1 mm;
Default setting: 25.4 mm
Foil warn stop
AP 5.4
AP 5.6
Off
(Default setting) Printer does
not
stop in case of a „Foil end warning“.
On
If a „Foil end warning“ occurs, the printer stops after the current label and
shows the status message:
Press the online button to acknowledge the message, then the feed button to
continue printing.
Print Interpret.
AP 5.4
AP 5.6
The printer uses the MONARCH LANGUAGE INTERPRETER™ to inter-
prete and process data.
Easyplug
Printjobs written in the Easy-Plug command language can be interpreted.
Lineprinter
Lineprinter (or similar to Lineprinter), print-out of the print command.
Hex Dump
Print-out in hexadecimal format.
In Lineprinter and Hex Dump, commands are printed out in the form of a list
with the character set 12.
When setting Lineprinter or Hex Dump, Easy Plug commands which have
not yet been processed are deleted!
ONLINE X JOBS
…to…
FOLIE X JOBS
…while the display is blinking.
PrintStatus: 5110
Foil low