![Novexx AP 5.4 Gen II User Manual Download Page 233](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055233.webp)
06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
91
For more information about saving and reading parameter settings read topic
section „Advanced Applications“, chapter „Saving and Transferring
parameter settings“.
Store Diagnosis
AP 5.4
AP 5.6
Stores the diagnostic data on memory card. The default file name composes
as follows:
„Diagnose AP 5.4 203 Dpi A429403110613.log“
•
AP 5.4 203 Dpi
: printer type and printhead resolution
•
A429403110613
: serial number of the CPU board; equals the value
displayed under
SERVICE DATA > CPU board data > Serial number
For details read the service manual, topic section „Fault Location“, chapter
„Reading out diagnostic data“.
Gen.Support Data
AP 5.4
AP 5.6
Generate support data
Generates the folder „SupportData“ on the selected memory medium and
stores the following diagnosis files therein:
•
Setup.for (for details see
SPECIAL FUNCTION > Store Parameters
)
•
SetupAll.for (for details see
SPECIAL FUNCTION > Store Parameters
)
•
Diagnose.log (for details see
SPECIAL FUNCTION >
Store diagnosis
)
Each of the file names is completed by the printer type and the serial number
of the CPU board. The file content is english, regardless of the language set-
ting at the printer.
Those data are very helpful for the technical support for fault diagnosis pur-
poses.
EasyPl. file log
Easy-Plug file log
AP 5.4
AP 5.6
Only visible, if a memory card is inserted.
Activating this parameter may slow down the label rate. Therefore disable
the function after error analysis.
Activating this parameter may cause error messages, which may be
difficult to understand. Therefore disable the function after error analysis. If
an error occurs, disable the function and restart the printer.
Off
The file log function is switched off.
All data
All received data, including immediate commands, are written into the log file.