![Novexx AP 5.4 Gen II User Manual Download Page 307](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055307.webp)
06/15 Rev. 10
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
56
Measure
Please read the notes in section
General software errors
.
5504 No
RFID
job
Status
A print job, which is not declared as RFID printjob, contains RFID-specific
Easy-Plug commands (e. g. #RT, #RFW, …).
RFID printjobs are declared in the #IM command by defining the distance
between label edge and optimum of transponder antenna (parameter "d").
Measure
Modify the print job.
5510
RFID COM timeout
Status
Timeout error. There was no communication between reader module and
COM2 in the time slot where it should be performed.
Measure
Repeat the operation, in the course of which the error occured.
Check, if the reader module board is connected correctly.
Check if the reader module board is defective.
5512
COM open failed
Status
There was a communication problem at COM2 while powering up the
printer. The interface cannot be opened by the printer firmware – or it is
used by another firmware part.
Measure
Check, if COM2 is available (that is, if it is built-in).
Check the function of the COM2 interface.
5513
Get baud failed
Status
There was a communication problem between COM2 and reader module
while powering up the printer. The baud rate of the reader module is not
detected correctly by the printer firmware. Baud rate and/or parity and/or
another setting of transmission parameters at the reader module is faulty.
Measure
Check, if the reader module board is connected correctly.
Check if the reader module board is defective.
Check the setting of the transmission parameters at the reader module.
5521 No
transponder
Status
Either there is no transponder (=tag) or more than one transponder within
reach of the antenna.
Measure
Check the label material feeding; remove paper jam, if necessary.
5522
Tag write err
Status
A transponder (=tag) cannot be written on for one of the following reasons:
•
Faulty address: e.g. an attempt to write into a protected area.
•
The tag is out of reach of the antenna, after it has already been recognized.
•
Noise signals avoid the transmission.
Measure
Check the system for the mentioned error causes and correct them.