14
1033
Uninit flash par
Status
General software error
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
1034 Uninit
restrict
Status
A „restricted string“ parameter could not be initialized.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
1035 Uninit
combi
Status
General software error. A combi parameter could not be initialized.
Measure
Confirm by pressing the Online button.
Please read the notes in section
General software errors
.
1036
Wrong combi para
Status
General software error. A combi parameter could not be initialized.
Measure
Confirm by pressing the Online button.
Please read the notes in section
General software errors
.
1037 Software
error
Status
General software error
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
1038 Software
error
Status
General software error
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
1087 OLV
not
active
Status
OLV- specific Easy Plug commands have been used (#OLVI or #OLVD),
without
having set the printer to OLV use at first.
Measure
Set the printer to OLV use.
See parameter
INTERF. PARAM > COM2 PORT > Function Option
.
1088 No
realtimeclock
Status
RTC-specific Easy Plug commands have been used (#YS or #YC),
without
having a RTC installed.
Measure
Install a RTC.
For details refer to the Service Manual, topic section "General Service",