USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
90
Factory settings
AP 5.4
AP 5.6
All parameters are preset ex works to values specific to each device type.
These factory settings can be restored at any time.
All parameters are then overwritten by the factory settings.
All data present in the spooler, including data belonging to an interrupted
print job, is deleted!
No
(Default) No factory setting.
Custom defaults
If custom parameter settings were stored before (see parameter
Custom de-
faults
), those are restored.
„Custom defaults“ only appears, if custom settings have already been
stored.
Factory defaults
The parameters are set to factory defaults.
Custom defaults
AP 5.4
AP 5.6
Parameter appears only in production mode.
Apply current
Stores the current parameter settings as values for the default setup. Those
settings are restored by calling parameter
SPECIAL FUNCTION >
Factory settings
=
„Custom defaults“.
Delete
Deletes the stored custom default settings. „Delete“ is only visible, if settings
have already been stored.
Store Parameters
AP 5.4
AP 5.6
Parameter settings are saved in a text file on memory card (directory
FORMATS\). Considered are also parameters which belong to options,
which are not activated.
Without adj. par
(Default) Parameters, which contain device specific settings, are
not
saved.
(Default file name: SETUP.FOR).
Application example
: Transfer of printer settings to another printer (device
specific settings as printhead resistance or sensor settings should not be
overwritten).
With adjust para
Parameters, which contain device specific settings, are
also
saved. The rel-
evant parameter names are marked with a * in the text file.
(Default file name: SETUPALL.FOR).
Application example
: Service