![Novexx AP 5.4 Gen II User Manual Download Page 185](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055185.webp)
06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
43
> COM1 PORT
Baud rate
AP 5.4
AP 5.6
Data transfer speed
Speed of data transfer using the serial interface.
xxxxxx Baud
Setting range: 300 to 115200 Baud; Unit interval: 300/600/1200/2400/4800/
9600/19200/38400/115200 (default)
No. of data bits
AP 5.4
AP 5.6
This parameter can be defined in connection with both the serial and the par-
allel interface.
7
7 Data bits
8
8 Data bits
Parity
AP 5.4
AP 5.6
Defines the parity check of serial transmitted data.
The parity bit is for checking data transmission. If the check shows an error,
a corresponding message is displayed. The setting must be identical at the
sender and the receiver. Normally transmission is set without a parity bit.
Odd
Odd parity.
A parity bit is added so that there is an odd number of 1 Bits.
Even
Even parity.
A parity bit is added so that there is an even number of 1 Bits.
None
No check bit. Sending and receiving without check bit.
Always zero
Check bit is always 0 (zero). Sending and receiving without parity check.
Stop bits
AP 5.4
AP 5.6
Number of stop bits
1 Bit
1 stop bit
2 Bit
2 stop bits