[10] Positive and negative offset in relation to the feed direction (arrow).
Bar code multip.
AP 5.4
AP 5.6
Bar code height scaling factor
Increases the bar code height defined in the label layout (Easy-Plug) by multi-
plication by a factor of 1 to 10.
x
Setting range: 1 to 10; Unit interval: 1; Default setting: 1
The printed bar code height calculates starting with the value defined in the
label layout multiplied by the scaling factor x.
Tradit. Imaging
AP 5.4
AP 5.6
In production mode only.
Up to firmware version x.31, the barcode height was calculated with the
formula:
with x =
PRINT PARAMETERS > Barcode Multi.
By doing so, the printed barcode height in millimeters was by 1 higher than
the value defined in the layout (1 --> 2 mm, 2 --> 3 mm, etc.)
1)
.
From firmware version x.31 on, the printed barcode is exactly as high in mil-
limeters, as the value in the layout is (1 --> 1 mm, 2 --> 2 mm, etc.)
1
.
No
New height calculation (1 --> 1 mm, 2 --> 2 mm, etc.) is applied (default set-
ting).
The plain copy line is printed with OCR-B font.
Yes
Setting for customers with print layouts based on the
old
height calculation
scheme.
1) Assumed that
PRINT PARAMETERS > Barcode Multi.
= „1“.
Barcodehight
Barcodehight
Layout
1
+
(
)