![Novexx AP 5.4 Gen II User Manual Download Page 184](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055184.webp)
06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
42
Printer ID No.
AP 5.4
AP 5.6
Printer identification number
Determines the
identification number of the printer. In such a way, the printer
can be addressed by the Easy Plug command #!An (n=printer ID).
The use of ID numbers is in particular reasonable for data transfer by RS422/
485 interface, if several printers are connected by one data line. Each of the
connected printers then only incorporates the data mapped to him by #!An
command.
xx
Setting range: 0 to 31; Unit interval: 1
Spooler size
AP 5.4
AP 5.6
The memory capacity of the printer buffer can be set according to the require-
ments of each customer.
xxx Kbyte
Unit interval: 16-2048 kBytes; step width: 16 kBytes; default setting:
64 kBytes
Offline mode
AP 5.4
AP 5.6
Interf. disabled
Easy-Plug commands are
not
accepted, while the machine is in offline mode
(default setting).
Interf. enabled
Easy-Plug commands
are
accepted in offline mode.
Interface delay
AP 5.4
AP 5.6
Only visible, if
INTERFACE PARA >EASYPLUGINTERPR > Offline mode
= „Interf.
enabled“
After switching from online to offline mode, the printer interface is deactivat-
ed. This parameter offers a setable delay time before deactivating the inter-
face.
xxxx ms
Setting range: 0-1000; Unit interval: 100; Default setting: 0