![Novexx AP 5.4 Gen II User Manual Download Page 187](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055187.webp)
06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
45
Even
Even parity.
A parity bit is added so that there is an even number of 1 Bits.
None
No check bit. Sending and receiving without check bit.
Stop bits
AP 5.4
AP 5.6
With mounted and connected I/O board only.
The number of stop bits is 2 and cannot be changed.
Data synch.
AP 5.4
AP 5.6
With mounted and connected I/O board only.
See parameter
Data synch.
on page 44.
Frame error
AP 5.4
AP 5.6
With mounted and connected I/O board only.
See parameter
Frame error
on page 44.
Serial Port Mode
AP 5.4
AP 5.6
With mounted and connected I/O board only.
Setting of the serial interface type.
RS232
Sets Com2 to RS 232.
Data synchronisation may be done by hardware (RTS/CTS) or by software
(XON/XOFF). Maximum cable length is 15 m.
RS422
Sets Com2 to RS 422.
RS 422 is a 4 wire point to point connection, suitable for only one device.
Receiver and driver of the printer are always enabled. Data synchronization
is only possible by software (XON/XOFF). Maximum cable length is 1 km with
twisted telecommunication cable.
RS485
Sets Com2 to RS 485.
RS 485 is a 2 or 4 wire bus system for up to 30 devices. The printer´s receiver
is always enabled, the printer´s driver is only enabled, if the printer sends
data to the host. Data synchronization is only possible by software (XON/
XOFF). Maximum cable length is 1 km with twisted telecommunication cable.