![Novexx AP 5.4 Gen II User Manual Download Page 182](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055182.webp)
06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
40
The range of the value automatically measured by the gap detection can be
defined specifically for the label material. This allows materials with high-con-
trast proof points within the label to be processed, which would otherwise be
measured as 'false' gaps by the system. The corresponding setting value is
then equal to, or smaller than, the value measured at the actual gap.
Punch level
AP 5.4
AP 5.6
Only if
PRINT PARAMETERS > Punch mode
= „Manual“.
xxx
Setting range: 0 to 255; Unit interval: 1
The value xxx stands for the current contrast within the photoelectric switch
of the material which has just been inserted. This serves to determine a
threshold value for the inserted material.
xxx = current measurement at the punch sensor
yyy = set threshold value
Example
Self-adhesive material with black bars lengthways across the label
•
Reading:
– Masking paper: 30
– Masking paper + label: 60
– Masking paper + label + black bars: 190
•
Setting value: 60
A setting value of 60 means that all readings over 60 are ignored, therefore
also the reading 190 at the black bar.
Punchlevel
Punch xxx Val yyy