![Novexx AP 5.4 Gen II User Manual Download Page 203](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055203.webp)
06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
61
Setting:
1. From the print head, read off the resistance value to be set and make a note
of it (1000 to 1500).
2. In off-line mode press the Prog. button, display:
PRINT INFO
.
3. Press the Cut button until
SYSTEM PARAMETER
is displayed.
4. Press the Online button, display:
5. Press the Cut button until the following is displayed:
6. Press the Online button, set value is displayed.
7. Set the previously noted resistance value of the print head using the Feed
and Cut buttons.
8. Press the Online button to confirm the set value.
9. Press the Prog. button to return to the display
OFFLINE 0 JOBS
.
Temp. reduction
AP 5.4
AP 5.6
Reduction in the print head temperature
The parameter
SYSTEM PARAMETER > Temperature reduct.
allows the power supply
to be reduced in the event of an increase in the print head temperature, there-
by ensuring an evenly good print image.
xxx%
Setting range: 0 to 100%; Unit interval: 5%
The following setting alternatives are available:
•
0%: No temperature reduction.
•
xx%: Up to xx% temperature reduction with a hot print head.
•
Default setting: 20%.
For further information refer to the user manual, topic section „Advanced
Application“, chapter „Printing with Termperature Compensation“
SYSTEM PARAMETER
Foil end warning
SYSTEM PARAMETER
Head resistance