![Novexx AP 5.4 Gen II User Manual Download Page 241](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055241.webp)
06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
99
Receive test
AP 5.4
AP 5.6
Serial connection
Assumption is a serial data line between PC and printer; the parameter
INTERF.PARAM. > Interface
must be set to „Serial Com1“.
1. Start the MS-DOS-prompt (using Windows).
2. Set the interface to the values adjusted at the printer by means of MS-DOS
command MODE:
Example of printer settings:
– Baud rate: 19200
– No. of data bits: 8
– Parity: none
– Stop Bits: 1
– Data synch.: RTS/CTS
DOS-Command:
mode COM1 baud=19200 parity=n data=8 stop=1
(if com1 is the serial port)
3. Press the Online-key to start Receive test.
4. Send any file to the printer (Condition: com1 = Printer port; anyfile.txt = any
file ):
copy anyfile.txt com1
(add /b for binary files)
The following shows up on the printer display:
xxxxxx is the size of the sent file in bytes. This value is being counted up dur-
ing the test. The test is complete if the file size does not vary any more. If the
bytes announced at the printer match the size visible in the MS-DOS window,
transfer was successful. Otherwise, transmission errors occurred.
Printtest
AP 5.4
AP 5.6
General printtest, prints line by line the set printer type and the firmware ver-
sion. Material settings (Material type, length, width) are considered.
Stop the printtest by pressing the Online button.
Receive test
0 Bytes
Receive test
xxxxx Bytes