![Novexx AP 5.4 Gen II User Manual Download Page 215](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055215.webp)
06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
73
Start source
AP 5.4
AP 5.6
Only if
SYSTEM PARAMETER > Periph. device
= „Dispenser“.
Choose a signal source for the start signal:
Foot switch
Optional foot switch is used to generate the start signal.
Light barrier
(Default setting) Photoelectric switch at the dispensing edge which detects
the taking off of the dispensed label.
The setting "Light barrier" is unsuitable for product sensors! Product
sensors must be connected to the I/O board!
Calibration mode
AP 5.4
AP 5.6
Only if
SYSTEM PARAMETER > Periph. device
= „Dispenser“.
Is only effective with label material shorter than 40 mm!
If label material shorter than 40 mm is used, the printer automatically in-
itializes before printing. This measuring of the label material improves
the impression accuracy. The initialization occurs in the following cases:
•
After switching the printer on
•
After opening and closing the printhead pressure lever.
Advice
: Start the material initialization manually before printing. This is
done by pressing the feed button in offline mode.
Selecting a material initialization procedure:
Automatic
(Default) Material initialization is done automatically. Therefore, the label ma-
terial is fed forwards and backwards several times.
There is a risk of the dispensing edge roller getting jammed by labels
sticking to it, which were dispensed by the forward/backward movement. If
this happens, use the setting „Manual“ instead.
Manual
The label material is fed two or three label lengths forwards. If this is done,
dispense two labels by pressing the feed button - only afterwards, the initial-
ization is complete.
Start offset
AP 5.4
AP 5.6
Function for operation with product sensor.
Use this parameter to set the distance between product sensor (light barrier)
and dispensing edge. The recommended delay time is calculated of the
"Start delay" distance and the conveyor speed (= print speed in cases of di-
rect application).
xxx.x mm
Setting range: 15.0 bis 2999.9 mm; Unit interval: 0.1 mm;
Default setting: 15.0 mm