![Novexx AP 5.4 Gen II User Manual Download Page 316](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055316.webp)
06/15 Rev. 10
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
65
8106 Fonttype
wrong
Status
General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
8107 Character
set
Status
General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
8108 Symbol
set
Status
General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
8109 TT-specifications
Status
General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
8110 Unknown
char.
Status
Character is not included in the character set (character set does not
support all characters).
Measure
Select another character / character set.
8111 Stream
type
Status
General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
8112 Font
not
supp.
Status
The applied Truetype font is not supported by the system. Text, which uses
this font, is ignored.
Measure
Use another Truetype font.
8200 Fixfont
number
Status
Incorrect fix font no.
Measure