![Novexx AP 5.4 Gen II User Manual Download Page 186](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055186.webp)
06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
44
Data synch.
AP 5.4
AP 5.6
Data synchronisation at the serial interface.
RTS/CTS
Data synchronisation through hardware
XON/XOFF
Data synchronisation through software
None
Handshake signals are ignored
Frame error
AP 5.4
AP 5.6
Display
(Default) An error message is displayed, if a framing error is detected while
the printer is receiving serial data.
Ignore
Framing errors will be ignored, no error messages are displayed.
> COM3 PORT
This menu only appears, if the optional I/O board is installed.
Baud rate
AP 5.4
AP 5.6
With mounted and connected I/O board only.
Speed of data transfer using the serial interface.
xxxxxx Baud
Setting range: 2400 to 115200 Baud; Unit interval: 2400/4800/9600/19200/
38400/115200 (default)
No. of data bits
AP 5.4
AP 5.6
With mounted and connected I/O board only.
The number of data bits is always 8.
Parity
AP 5.4
AP 5.6
With mounted and connected I/O board only.
Defines the parity check of serial transmitted data.
The parity bit is for checking data transmission. If the check shows an error,
a corresponding message is displayed. The setting must be identical at the
sender and the receiver. Normally transmission is set without a parity bit.