![Novexx AP 5.4 Gen II User Manual Download Page 261](http://html1.mh-extra.com/html/novexx/ap-5-4-gen-ii/ap-5-4-gen-ii_user-manual_1712055261.webp)
06/15 Rev. 10
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
10
Listing of all Status reports
1000
No new command
Status
General software error
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
1001 Parameter
Table
Status
General software error
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
1002 Comm.
sorting
Status
General software error
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
1003
Too many slashes
Status
General software error
Measure
Please read the notes in section
General software errors
.
1004
Slash w/o param.
Status
General software error
Measure
Acknowledge by pressing the on-line button.
Please read the notes in section
General software errors
.
1005
2 same commands
Status
General software error
Measure
Acknowledge by pressing the on-line button.
Please read the notes in section
General software errors
.
1006 Letter
incorrect
Status
General software error: self-acknowledging
Measure
Please read the notes in section
General software errors
.
1007 Command
incorr.
Status
Unknown
command.
Measure
Check Easy Plug sequence.
1008 Subcomm.
incorr.
Status
Unknown letter in a subcommand.
Measure
Check Easy Plug sequence.