30
1519 Cmd
Init
Error
Error level
1
Status
General software error.
Measure
Read
chapter
General software errors
on page 8.
1520 Unsupported
Cmd
Error level
1
Status
Non critical commands that is not supported by this printer.
Measure
Check and modify the commands in the printjob.
1521 Unsupported:
x
Error level
2
Status
Critical commands that is not supported by this printer.
Measure
Check and modify the commands in the printjob.
1522
Bad Char Set x
Error level
2
Status
The character set selected by ^CI command is not supported.
Measure
Replace the character set by a supported set.
1523
Cmd Parm Error
Error level
1
Status
Error encountered while parsing command parameter.
Measure
Check and modify the commands in the printjob.
1524
d/mm not chg x
Error level
2
Status
Command attempting to lower print density assuming a 200 dpi printer.
Measure
Check and modify the commands in the printjob.